Human Immunodeficiency Virus Types 1 and 2 (HIV-1/2) Antibody Differentiation, Supplemental, With Reflex to HIV-1/HIV-2 by Qualitative NAAT: ARUP Laboratories test 2012669
ARUP Laboratories test 2012669, CPT 86701, 86702, 87535, 87538. Specimen: Serum separator tube (SST), lavender (EDTA), or pink (K2EDTA).. Turnaround: 1-2 days.
Human Immunodeficiency Virus Types 1 and 2 (HIV-1/2) Antibody Differentiation, Supplemental, With Reflex to HIV-1/HIV-2 by Qualitative NAAT is ARUP Laboratories test code 2012669, billed with CPT 86701, 86702, 87535, 87538. Specimen: Serum separator tube (SST), lavender (EDTA), or pink (K2EDTA).. Turnaround time: 1-2 days. Performing laboratory: ARUP Laboratories, CLIA
46D0523979 (Salt Lake City, UT). Other labs in the directory with tests billed under the same CPT: Labcorp.
Test code2012669
CPT86701; 86702; if reflexed, add 87535; 87538
LOINC29893-5, 30361-0, 77202-0, 80203-3
SpecimenSerum separator tube (SST), lavender (EDTA), or pink (K2EDTA).
Turnaround time1-2 days
Storage / transportFrozen.
Also known as: Geenius; HIV Diagnosis; HIV Multispot; HIV-1 & 2 Antibody Differentiation; HIV-1 and HIV-2 Antibody Differentiation; HIV-1 Antibody by Multispot; Human Immunodeficiency Virus 1/2 (HIV-1/2) Antibody, Differentiation With Reflex to HIV-1/HIV-2 RNA
Use
Useful as a supplemental assay for repeatedly reactive third- or fourth-generation HIV screen tests when following the CDC's recommended HIV testing algorithm. This test should not be used as a rapid screen or as a follow-up test for a positive rapid screen.
Methodology
Qualitative Polymerase Chain Reaction (PCR) / Qualitative Immunoassay
Collection instructions
Separate from cells within 24 hours of collection. Transfer 3 mL serum or plasma into an ARUP standard transport tube dedicated only for the HIV AB DIF assay. (Min: 1.5 mL) Remove particulate material. SHIP FROZEN.
Stability
After separation from cells: Ambient: 24 hours (SHIP FROZEN); Refrigerated: 5 days; Frozen: 6 weeks (avoid repeated freeze/thaw cycles)
Causes for rejection
Heparinized or citrated plasma specimens. Specimens containing particulate material. Severely hemolyzed or heat-inactivated specimens.
Reference range
Test Number
Components
Reference Interval
HIV-1 Antibody
Negative
HIV-2 Antibody
Negative
Performed
Varies
Compliance Category
FDA
New York DOH Approval Status
This test is New York state approved.
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|
| 2012670 | HIV-1/2 Ab Differentiation Immunoassay | | 77202-0 |
| 2012671 | HIV-1 Antibody | | 29893-5 |
| 2012672 | HIV-2 Antibody | | 30361-0 |
| 2012673 | HIV Serologic Interpretation | | 80203-3 |
View this test on ARUP Laboratories's website → · Last checked 2026-11-29
Other tests billed with CPT 86701, 86702, 87535
- Human Immunodeficiency Virus (HIV) Combo Antigen/Antibody (HIV-1/O/2) by CIA with Reflex to HIV-1/HIV-2 Antibody Differentiation, Supplemental
ARUP LaboratoriesTest code 2013333CPT 86701, 86702, 87389Serum separator tube (SST). Also acceptable: Lavender (EDTA) or pink (K2EDTA).TAT 1-2 days
- Human Immunodeficiency Virus (HIV) Combo Antigen/Antibody (HIV-1/O/2) by CIA, Reflexive Panel
ARUP LaboratoriesTest code 2012674CPT 86701, 86702, 87389, 87535, 87538Serum separator tube (SST), lavender (EDTA), or pink (K2EDTA).TAT 1-2 days
- Human Immunodeficiency Virus Types 1 and 2 (HIV-1/2) Antibody Differentiation, Supplemental
ARUP LaboratoriesTest code 2013107CPT 86701, 86702Serum separator tube (SST), lavender (EDTA) or pink (K2EDTA).TAT 1-2 days
- Human Immunodeficiency Virus 1 & 2 (HIV-1/HIV-2), Qualitative, RNA
LabcorpTest code 139825CPT 87535, 87538Plasma or serumTAT 2 - 5 days
- Human Immunodeficiency Virus 1 and 2 (HIV-1/HIV-2) by Qualitative NAAT
ARUP LaboratoriesTest code 3017779CPT 87535, 87538Lavender (EDTA), pink (K2EDTA), plasma preparation tube (PPT), or serum separatoTAT 1-4 days
- PrEP Use Only: HIV Antigen/Antibody and HIV RNA, Qualitative
LabcorpTest code 083971CPT 87389, 87535, 87538SerumTAT 3 - 5 days
- PrEP Use Only: Human Immunodeficiency Virus 1 & 2 (HIV-1/HIV-2), Qualitative, RNA
LabcorpTest code 083973CPT 87535, 87538Plasma or serumTAT 2 - 5 days
- PrEP, Female, Injectable Baseline + HIV RNA
LabcorpTest code 254988CPT 84702, 86704, 86706, 86780, 86803, 87340, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Injectable Monitor + HIV RNA
LabcorpTest code 254801CPT 84702, 86780, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Oral Baseline + HIV RNA
LabcorpTest code 254855CPT 82565, 84702, 86704, 86706, 86780, 86803, 87340, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Female, Oral Monitor + HIV RNA
LabcorpTest code 254880CPT 84702, 86780, 87389, 87491, 87535, 87538, 87591Serum and first-void urine (patient should not have urinated for one hour prior TAT 2 - 3 days (testing performed daily)
- PrEP, Male, Injectable Baseline + HIV RNA
LabcorpTest code 254972CPT 86704, 86706, 86780, 86803, 87340, 87389, 87491, 87535, 87538, 87591Serum and urineTAT 2 - 3 days (testing performed daily)
- PrEP, Male, Injectable Monitor + HIV RNA
LabcorpTest code 254736CPT 86780, 87389, 87491, 87535, 87538, 87591Serum and urineTAT 2 - 3 days (testing performed daily)
- PrEP, Male, Oral Baseline + HIV RNA
LabcorpTest code 254842CPT 82565, 86704, 86706, 86780, 86803, 87340, 87389, 87491, 87535, 87538, 87591Serum and urineTAT 2 - 3 days (testing performed daily)
- PrEP, Male, Oral Monitor + HIV RNA
LabcorpTest code 254868CPT 86780, 87389, 87491, 87535, 87538, 87591Serum and urineTAT 2 - 3 days (testing performed daily)
Search the National Lab Test Directory · All ARUP Laboratories tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation