Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Vancomycin, peak

Vancomycin, peak: Allina Health Laboratory (Abbott Northwestern) test 964

Allina Health Laboratory (Abbott Northwestern) test 964, CPT 80202. Specimen: Serum or Lithium heparin (Li hep) plasma. Turnaround: 1 day.

Vancomycin, peak is Allina Health Laboratory (Abbott Northwestern) test code 964, billed with CPT 80202. Specimen: Serum or Lithium heparin (Li hep) plasma. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories, OHSU Laboratory Services, ARUP Laboratories, Labcorp.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code964
CPT80202
LOINC—
SpecimenSerum or Lithium heparin (Li hep) plasma
Volume1.0 mL
Minimum volume0.2 mL
ContainerLt green plasma separator (PST) Gold serum separator (SST) tube Red serum vial/tube, 5 mL
Turnaround time1 day

Also known as: Vancocin

Methodology

Kinetic interaction of microparticles in a solution (KIMS)

Collection instructions

Draw 15 or 30 minutes after IV dose depending on providers orders Immediately following collection, mix sample thoroughly by gentle inverting 8 - 10 times

Stability

Refrigerated (preferred) - 14 days Ambient - 2 days Frozen - 12 months Allina performed internal stability studies on the Roche platform and validated gel tubes acceptable for testing.

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Inappropriate timing of collection Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

20 - 40 µg/mL Results that require action (critical): >60 µg/mL

Performed

Daily

Abbreviation

VNP

Order number

80202.3

Transport container

Lt green plasma separator (PST)/Gold serum separator (SST) tube Lt green plasma separator (PST) Gold serum separator (SST) tube Red: False bottom plasma/serum transport vial/tube (AHL)

Performing Laboratory

AHL - Chemistry: C

Processing instructions

Green/Gold: Spin within two (2) hours of sample collection Red: Allow sample to clot Spin Transfer serum to a False bottom plasma/serum transport vial/tube (AHL) , labelled as serum, within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 80202

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation