Vancomycin, Serum, Peak: Labcorp test 070327
Labcorp test 070327, CPT 80202. Specimen: Serum or plasma. Turnaround: Within 1 day.
Also known as: Vancocin®
Use
Use of intravenous vancomycin should be restricted to serious infections caused by susceptible staphylococci or other gram-positive bacteria when other antibiotics are ineffective or not tolerated. Vancomycin is the drug of choice for serious infections caused by methicillin-resistant Staphylococcus aureus and coagulase-negative staphylococci (including S epidermidis ). These infections include septicemia, endocarditis, osteomyelitis, pneumonia, lung abscesses, soft tissue infections, wound infections, and meningitis. Lumbar intrathecal or intraventricular administration may be required to treat meningitis. Methicillin-resistant Staphylococcus epidermidis (and other coagulase-negative…
Methodology
Immunoassay
Collection instructions
Transfer separated serum or plasma to a plastic transport tube. Both peak and trough concentrations should be monitored. The trough sample is drawn immediately prior to the next dose.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 3 days |
| Refrigerated | 14 days |
| Frozen | 14 days |
| Freeze/thaw cycles | Stable x3 |
Causes for rejection
Gel-barrier tube; hemolysis; lipemia; gross bacterial contamination
Reference range
• Therapeutic : 25.0−40.0 μg/mL Note: Peak levels drawn at 30 minutes are more variable and very dependent on consistent timing of collections. Differences of as little as 15 minutes in sampling time can result in a 10−15 μg/mL difference in measured vancomycin concentrations. It is important that consistency be maintained in the dosage interval and infusion period throughout the course of therapy for comparison of vancomycin concentrations to be valid. Peak levels collected at two hours are less variable. • Therapeutic : 25.0−40.0 μg/mL • Detection limit: 2.0 μg/mL; <2.0 μg/mL indicates none detected Note: Peak levels drawn at 30 minutes are more variable and very dependent on consistent timing of collections. Differences of as little as 15 minutes in sampling time can result in a 10−15 μg/mL difference in measured vancomycin concentrations. It is important that consistency be maintained in the dosage interval and infusion period throughout the course of therapy for comparison of vancomycin concentrations to be valid. Peak levels collected at two hours are less variable. • Therapeutic : 25.0−40.0 μg/mL Note: Peak levels drawn at 30 minutes are more variable and very dependent on consistent timing of collections. Differences of as little as 15 minutes in sampling time can result in a 10−15 μg/mL difference in measured vancomycin concentrations. It is important that consistency be maintained in the dosage interval and infusion period throughout the course of therapy for comparison of vancomycin concentrations to be valid. Peak levels collected at two hours are less variable.
Special instructions
Peak levels should be ordered using Test No. 070327. Trough levels should be ordered using Test No. 070328. Please label tubes appropriately as "peak" and "trough."
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 070333 | Vancomycin Peak, Serum | ug/mL | 4090-7 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 80202
- Vancomycin
- Vancomycin
- Vancomycin Level, Random, Serum
- Vancomycin Level, Trough, Serum
- Vancomycin, Serum, Trough
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.