Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Rh

Rh: Allina Health Laboratory (Abbott Northwestern) test 6062

Allina Health Laboratory (Abbott Northwestern) test 6062, CPT 86901, 86905. Specimen: EDTA whole blood. Turnaround: 1 day.

Rh is Allina Health Laboratory (Abbott Northwestern) test code 6062, billed with CPT 86901, 86905. Specimen: EDTA whole blood. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Quest Diagnostics, Labcorp, Cleveland Clinic Laboratories, OHSU Laboratory Services.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code6062
CPT86901; 86905 - Weak D (Du) (If appropriate)
LOINC—
SpecimenEDTA whole blood
Volume4.0 mL
ContainerLavender (EDTA), 4mL
Turnaround time1 day

Also known as: Big D; D; Rhesus factor; Rho; Tests included:; For questionable, discrepant, or weak serologic reactions, Rh type may reflex molecular variant D testing.; Paternal testing for D determination is a BB Misco. For paternal testing for D determination, D variant molecular testing will be completed.

Use

Detection of the D (RH1) antigen on red blood cells. May be used in the determination of the mother's candidacy for Rh immune globulin therapy. Limitations: Testing should be performed within 7 days of collection Very weak expressions of the Rh D antigen may not be detected using traditional serologic methodologies

Methodology

Agglutination Column-agglutination

Collection instructions

Immediately after collection, mix tube thoroughly by gentle inversion, 8 - 10 times, to prevent clotting Labelling instructions: Excellian sites: Tube must be labeled with the patients first and last name and Excellian MRN, date and time of collection and phlebotomist’s A# Non-Excellian sites: Tube must be labeled with the patient's first and last name and date of birth, date and time of collection and phlebotomist’s initials.

Stability

Refrigerated - 7 days

Causes for rejection

Improper label (unlabeled or mislabeled) Hemolysis

Reference range

A positive test indicates the presence of the D antigen.

Performed

Daily

Abbreviation

RHD

Order number

86901.1

Transport container

Lavender (EDTA), 4mL

Performing Laboratory

AHL - Blood Bank: B

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 86901, 86905

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation