Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › ABO Group and Rh Type

ABO Group and Rh Type: Quest Diagnostics test 7788

Quest Diagnostics test 7788, CPT 86900, 86901.

ABO Group and Rh Type is Quest Diagnostics test code 7788, billed with CPT 86900, 86901. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code7788
CPT86900, 86901
LOINC—
Minimum volume5 mL
ContainerEDTA (pink-top) tube
Storage / transportRoom temperature

Also known as: Type and Group; Blood Type

Methodology

Immune Agglutination

Collection instructions

If submitting with a CBC, HbA1c, or any other test requiring an EDTA (lavender-top) tube, please submit a separate tube for this test

Stability

TemperaturePeriod
Room temperature72 hours
Refrigerated7 days
FrozenUnacceptable

Patient preparation

None Specified Preferred specimen(s) 5 mL whole blood collected in an EDTA (pink-top) tube

Causes for rejection

Gross hemolysis • Serum separator tube (SST) • Spun red-top tube (no gel)

Reference range

See Laboratory Report

Alternative specimen(s)

ACD (yellow-top) tube • Red-top tube (unspun no gel) • Cord blood • EDTA (lavender-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86900, 86901

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation