Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Glucose tolerance, 2 hr standard (non-pregnant patients)

Glucose tolerance, 2 hr standard (non-pregnant patients): Allina Health Laboratory (Abbott Northwestern) test 240

Allina Health Laboratory (Abbott Northwestern) test 240, CPT 82947, 82950. Specimen: Lithium heparin (Li hep) plasma. Turnaround: 1 day.

Glucose tolerance, 2 hr standard (non-pregnant patients) is Allina Health Laboratory (Abbott Northwestern) test code 240, billed with CPT 82947, 82950. Specimen: Lithium heparin (Li hep) plasma. Turnaround time: 1 day. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Labcorp, Quest Diagnostics, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code240
CPT82947 - Fasting glucose; 82950 - Glucose post dose; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenLithium heparin (Li hep) plasma
Volume1.0 mL
ContainerLt green plasma separator (PST)
Turnaround time1 day

Also known as: GTT; FreshTest; Fresh Test; Alternative; Alternate

Use

The standard 2 hour glucose tolerance test is useful for screening for type 2 diabetes in non-pregnant patients. Limitations: Allina Health provides an FDA-approved prescription glucose drink that is free from dyes and is certified kosher. An order for an Alternative Glucose Tolerance, 2 hr (LAB15142) must be placed by the provider , if the decision is made to use an alternate source. See patient preparation information on Specimen tab for more details

Methodology

Hexokinase

Collection instructions

Draw a fasting specimen Immediately following collection, mix sample thoroughly by gentle inverting 8 - 10 times to prevent clotting If the fasting glucose is >126, cancel the testing as not indicated and notify the ordering physician Give fasting patient 75 gm glucose solution Must be consumed within 10 minutes Draw second specimen at 2 hours Label with time and hour collected

Stability

Serum/plasma: Refrigerated - 3 days Ambient - 8 hours

Patient preparation

Fasting is required prior to sample collection Fasting for a blood test The decision to use alternate glucose source for OGTT testing, is the responsibility of the treating provider and patient and must be ordered by the provider. The provider must place the appropriate Alternative Glucose Tolerance, 2 hr (LAB15142) and provide any instructions to the patient. Testing will be delayed if a standard OGTT order was placed and the patient comes to the lab with an alternate glucose source. The patient must bring the alternate glucose source for the test. The laboratory does not provide alternate glucose sources or give patient instructions for using alternate sources. If a patient shows up with an outside glucose drink or candy but the provider placed a standard GTT order, testing cannot proceed until the provider places the correct order.

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Inappropriate timing of collection Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

Fasting: 70 - 99 mg/dL 2 hr: 70 - 139 mg/dL

Performed

Daily

Abbreviation

GT2

Order number

LAB240

Alternate container

Gold serum separator (SST) tube Grey Sodium flouride (NaFl) Lavender (EDTA), 4mL Alternate processing instructions: Gold: Allow sample to clot for a minimum of 30 minutes Spin within two (2) hours of sample collection Dk green/lavender: Spin Transfer the plasma to an AHL False Bottom Plasma/Serum Transport Tube labeled as the appropriate plasma type, within two (2) hours of sample collection Grey: If a grey top tube will not reach the Central Laboratory within 24 hours of collection, it should be spun down, and the plasma transferred to an AHL False Bottom Plasma/Serum Transport Tube labeled as NaFl plasma. Additional testing cannot be added on to this sample. Alternate transport container: Gold serum separator (SST) tube Grey Sodium flouride (NaFl) or False bottom plasma/serum transport vial/tube (AHL)

Alternate specimens

Serum Sodium fluoride (Na Fl) whole blood or plasma EDTA plasma

Transport container

Lt green plasma separator (PST)

Performing Laboratory

AHL - Chemistry: C

Processing instructions

Spin within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 82947, 82950

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.