Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Allina Health Laboratory (Abbott Northwestern) › Prostatic specific antigen, total

Prostatic specific antigen, total: Allina Health Laboratory (Abbott Northwestern) test 1097

Allina Health Laboratory (Abbott Northwestern) test 1097, CPT 84153. Specimen: Serum. Turnaround: 1 - 2 days.

Prostatic specific antigen, total is Allina Health Laboratory (Abbott Northwestern) test code 1097, billed with CPT 84153. Specimen: Serum. Turnaround time: 1 - 2 days. Performing laboratory: Allina Health Laboratory (Abbott Northwestern), CLIA 24D0401558 (Minneapolis, MN). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services.
LaboratoryAllina Health Laboratory (Abbott Northwestern)
CLIA number24D0401558
Test code1097
CPT84153; Subject to medical necessity (Y/N):; Yes; LCD/NCD:; Medical necessity
LOINC—
SpecimenSerum
Volume1.0 mL
Minimum volume0.2 mL
ContainerGold serum separator (SST) tube
Turnaround time1 - 2 days

Also known as: PSA total

Use

The test method changed on 1/3/2023 . If this test has been used for serial monitoring, rebaselining is recommended. Rebaselining consists of 2 measurements, collected 3-6 weeks apart. The Roche Elecsys CEA assay is an electrochemiluminescence immunoassay "ECLIA" performed on the Roche Cobas "e" immunoassy analyzers. Values obtained with different assay methods may be different and cannot be used interchangeably.

Methodology

Electrochemiluminescence immunoassay (ECLIA)

Collection instructions

It is recommended to obtain specimens for PSA testing prior to procedures involving manipulation of the prostate. Immediatley following collection, mix sample by inverting 5 times.

Stability

Refrigerated (preferred) - 5 days Frozen - 6 months Ambient - 24 hours

Causes for rejection

Improper labels (unlabeled or mislabeled) Hemolysis (some procedures) Improper anticoagulant or ratio Delay in transport Improper storage temperature affecting results Improper container Leaking container resulting in compromised specimen Quantity not sufficient (QNS)

Reference range

< 4.00 ng/mL

Performed

Daily

Abbreviation

PSA

Order number

84153.0

Alternate container

Red serum vial/tube, 5 mL Red serum vial/tube, 10 mL Lt green plasma separator (PST) Alternate collection instructions: Immediatley following collection, mix sample by inverting 5 times Alternate processing instructions: Red: Allow sample to clot Spin Transfer serum to a False bottom plasma/serum transport vial/tube (AHL), labelled as serum, within two (2) hours of sample collection Lt green: Spin within two (2) hours of sample collection Alternate transport container: False bottom plasma/serum transport vial/tube (AHL)

Alternate specimens

Serum Lithium heparin (Li hep) plasma

Transport container

Gold serum separator (SST) tube

Performing Laboratory

AHL - Chemistry: C

Processing instructions

Allow sample to clot for a minimum of 30 minutes Spin within two (2) hours of sample collection

View this test on Allina Health Laboratory (Abbott Northwestern)'s website → · Last checked 2026-11-29

Other tests billed with CPT 84153

Search the National Lab Test Directory · All Allina Health Laboratory (Abbott Northwestern) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation