Prostate Health Index (phi) Profile: Labcorp test 140405
Labcorp test 140405, CPT 84153. Specimen: Serum, frozen. Turnaround: 3 - 5 days.
Test includes
Total PSA; free PSA; and p2PSA when total is between 4.0 and 10.0 ng/mL. If reflex testing is performed, additional charges/CPT code(s) may apply.
Use
The Access Hybritech PSA assay is indicated for the measurement of serum PSA in conjunction with digital rectal examination (DRE) as an aid in the detection of prostate cancer in men aged 50 year or older. This test is further indicated for the serial measurement of PSA to aid in the prognosis and management of patients with prostate cancer. The Access Hybritech free PSA assay is intended to be used with Hybritech (total) PSA to calculate the ratio of free PSA to total PSA expressed as a percentage (percent free PSA). Percent free PSA as measured by the Hybritech assays is indicated for use as an aid in distinguishing prostate cancer from benign prostatic conditions, when used in…
Methodology
PSA and fPSA concentrations are dependent on the standard used to calibrate the assays. PSA and fPSA concentrations reported by Labcorp for this assay are based on the Beckman Coulter Hybritech calibration standards. It should be noted that a PSA range of 4 to 10 ng/mL using Hybritech calibration corresponds to a PSA range of 3.1 to 7.8 ng/mL using WHO calibration. The Beckman Coulter phi scores will also be different if the PSA and free PSA tests used to derive the Beckman Coulter phi score were WHO-calibrated. Beckman Access Hybritech PSA, fPSA and p2PSA are performed and used to calculate the Beckman Coulter phi .
Collection instructions
Transfer serum to a plastic transport tube before freezing. To avoid delays in turnaround time when requesting multiple tests on frozen samples, please submit separate frozen specimens for each test requested.
Stability
| Temperature | Period |
|---|---|
| Room temperature | 3 hours (stability provided by manufacturer or literature reference) |
| Refrigerated | 24 hours (stability provided by manufacturer or literature reference) |
| Frozen | 5 months (stability provided by manufacturer or literature reference) |
| Freeze/thaw cycles | Stable x3 (stability provided by manufacturer or literature reference) |
Causes for rejection
Plasma or whole blood specimen
Reference range
Total PSA: 0.0–3.9 ng/mL Total PSA is the first test performed for the Prostate Health Index score (P score). If the total PSA result is in the range of 4 to 10 ng/mL, then reflex testing of free PSA and p2PSA, along with calculation of the P score and percent free PSA, will be added. Additional charges will apply. Testing was performed with Beckman Coulter unicel Dxl 800 assays using Hybritech calibration. Results obtained with different test methods or kits cannot be used interchangeably. PSA results calibrated to the WHO standard are approximately 20 percent lower than with the Hybritech calibration. Serum PSA in conjunction with digital rectal examination (DRE) is used as an aid in the detection of prostate cancer in men aged 50 years or older. Prostate biopsy is required for the diagnosis of cancer. Results cannot be interpreted as absolute evidence of the presence or absence of malignant disease. Prostate Health Index Score The Prostate Health Index (P score) is indicated for use as an aid in distinguishing prostate cancer from benign prostatic conditions, for prostate cancer detection in men aged 50 years and older with total PSA between 4 and 10 ng/mL, and with digital rectal examination findings that are not suspicious of cancer. Probability of prostate cancer on biopsy based on P score in patients with PSA between 4 and 10 ng/mL: P score Probability of Cancer 95% Confidence Interval 0–26.9 9.8% 5.2–15.4% 27.0–35.9 16.8% 11.3–22.2% 36.0–54.9 33.3% 26.8–39.9% >54.9 50.1% 39.8–61.0% The P score may also be used to determine the probability of prostate cancer on biopsy for an individual patient. Higher P scores are associated with higher probability of prostate cancer. Prostatic biopsy is required for diagnosis of cancer. Testing is performed with Beckman Coulter unicel DxI 800 Access PSA, Free PSA, and p2PSA assays using Hybritech calibration. Results obtained with different assay methods or kits cannot be used interchangeably. Results cannot be interpreted as absolute evidence of the presence or absence of malignant disease. Free PSA Percent Probability of prostate cancer for men with non-suspicious digital rectal exam (DRE) results and PSA between 4 and 10 ng/mL by patient age: Percent Free PSA 50 to 64 y 65 to 75 y 0–10% 56% 55% 11–15% 24% 35% 16–20% 17% 23% 21–25% 10% 20% >25% 5% 9% Testing was performed with Beckman Coulter unicel DxI 800 Access PSA and free PSA assays using Hybritech calibration. Results obtained with different assay methods or kits cannot be used interchangeably. Results cannot be interpreted as absolute evidence of the presence or absence of malignant disease.
Special instructions
Specimens should not be drawn immediately after digital rectal examination (DRE), prostatic massage or transrectal ultrasound (TRUS). PSA sampling should not be performed for at least six weeks after prostatic biopsy. Values obtained with different assays should not be used interchangeably in serial testing. It is recommended that only one assay method be used consistently to monitor each patient's course of therapy. This procedure does not provide serial monitoring; it is intended for one-time use only.
Limitations
The concentration of fPSA and PSA in a given specimen determined with assays from different manufacturers can vary due to differences in assay methods and reagent specificity. PSA concentrations are dependent on the standard used to calibrate the assay. Values obtained with different manufacturers' assays cannot be used interchangeably. If, in the course of monitoring a patient, the assay method used for determining PSA levels serially is changed, additional sequential testing should be carried out to confirm baseline values. PSA concentrations based on calibration to the WHO 96/670 Reference Preparation will differ significantly from PSA concentrations based on calibration to the original…
LOINC map
| Result code | Result name | Units | Result LOINC |
|---|---|---|---|
| 140406 | Prostate Specific Ag | ng/mL | 2857-1 |
View this test on Labcorp's website → · Last checked 2026-11-29
Other tests billed with CPT 84153
- Prostate Cancer Profile II (Serial Monitor)
- Prostate Health Index
- Prostate Health Index
- Prostate Specific Antigen, Free Percentage (Includes Free PSA and Total PSA)
- Prostate Specific Antigen, Total
- Prostate Specific Antigen, Total with Reflex to Free PSA (Includes Free Percentage)
- Prostate Specific Antigen, Ultrasensitive
- Prostate-specific Antigen (PSA)
- Prostate-specific Antigen (PSA) (Serial Monitor)
- Prostate-specific Antigen (PSA), Free:Total Ratio Reflex
- Prostate-specific Antigen (PSA), Free:Total Ratio Reflex (Serial Monitor)
- Prostate-specific Antigen (PSA), Ultrasensitive
- Prostate-specific Antigen (PSA), Ultrasensitive (Serial Monitor)
- PSA
- PSA, Screening
Search the National Lab Test Directory · All Labcorp tests and CLIA locations
Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation