Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Connexin 30 (GJB6) DNA Test

Connexin 30 (GJB6) DNA Test: Quest Diagnostics test 94009

Quest Diagnostics test 94009, CPT 81254.

Connexin 30 (GJB6) DNA Test is Quest Diagnostics test code 94009, billed with CPT 81254. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: OHSU Laboratory Services, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code94009
CPT81254
LOINC—
Minimum volume6 mL • Pediatric: 1 mL
ContainerEDTA (lavender-top) tube
Storage / transportRoom temperature

Also known as: CX30; gap junction protein; beta-6

Methodology

Polymerase Chain Reaction (PCR) • Fragment Size Analysis

Collection instructions

Please label each specimen tube with two forms of patient identification. These forms of identification must also appear on the test requisition. Note: Higher blood volumes ensure adequate DNA quantity, which varies with WBC, specimen condition, and need for confirmatory testing. Patients, 0-3 years have higher WBC, yielding more DNA per mL of blood. DNA yields and quality are better in fresh specimens. However, when necessary, most genetic tests are successful from DNA purified from whole blood that is several days old.

Stability

TemperaturePeriod
Room temperature10 days
Refrigerated10 days
FrozenUnacceptable

Patient preparation

None Specified Preferred specimen(s)

Causes for rejection

Gross hemolysis • Received frozen

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Athena Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81254

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation