Quest Diagnostics test 93945. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube or ACD (yellow-top) tube.

Hereditary Cancer Single Site(s) is Quest Diagnostics test code 93945. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube or ACD (yellow-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code93945
CPTCPT coding is dependent on the gene requested and analyzed. Confirmation of Patient Informed Consent for Genetic Testing This genetic test requires provider confirmation that patient informed consent has been received if the ordering provider is located in AK, AZ, DE, FL, GA, IA, MA, MN, MT, NV, NH,
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) tube or ACD (yellow-top) tube
Minimum volume2 mL whole blood • 2 mL saliva • 1 buccal swab • 10 mg skin fibroblasts • 2 flasks 75% confluent • 10 mL amniotic fluid • 10 mg chorionic villi
ContainerEDTA (lavender-top) tube or ACD (yellow-top) tube
Storage / transportRoom temperature

Also known as: BRCA; Familial mutation; Known familial mutation

Methodology

DNA Bait Capture • Long Range Polymerase Chain Reaction • Next Generation Sequencing • Microarray

Collection instructions

Do not hold specimen. Forward to laboratory when specimen arrives. Whole blood: Normal phlebotomy procedure. Specimen stability is crucial. Store and ship room temperature immediately. Do not freeze. Saliva: 2 mL saliva collected in the Oragene-Dx collection kit up to the "fill to" line (OGD-500/OGD-600, OGD-510/OGD-610). Do not remove the plastic film from the funnel lid. For fibroblasts and skin fibroblasts, call 1-866-GENEINFO (1-866-436-3463) prior to collecting and ordering. ⁠⁠⁠⁠⁠⁠⁠For fetal testing 1) Please call 1-866-GENE-INFO (1-866-436-3463) prior to submission 2) Documentation of parental carrier status must be provided 3) It is required that Maternal Cell Contamination Study, STR Analysis be ordered in conjunction with fetal testing. A separate tube of maternal blood (EDTA) is required for this test. Amniocyte or chorionic villus (CVS) culture: Two sterile T25 flasks, 75% confluent, filled with culture medium. Specimen stability is crucial. Store and ship at room temperature immediately. Do not refrigerate or freeze. Forward to laboratory when cells arrive. Amniotic fluid: Normal collection procedure. Specimen stability is crucial. Store and ship room temperature immediately. Do not refrigerate or freeze. Forward to laboratory when sample arrives. Dissected chorionic villus (CVS) biopsy: 10-20 mg dissected chorionic villi collected in sterile tube, filled with sterile culture medium. Specimen stability is crucial. Store and ship at room temperature immediately. Do not refrigerate or freeze. Forward to laboratory when sample arrives.

Stability

Whole blood Room temperature: 14 days Refrigerated: 14 days Frozen: Unacceptable Saliva or buccal swab Room temperature: 14 days Refrigerated: 14 days Frozen: 14 days Fibroblasts and skin fibroblasts Room temperature: 48 hours Refrigerated: Unacceptable Frozen: Unacceptable ⁠⁠⁠⁠⁠⁠⁠ Fetal specimen (cultured cells, amniotic fluid, chorionic villi) Room temperature: 48 hours Refrigerated: Unacceptable Frozen

Patient preparation

⁠⁠⁠⁠⁠⁠⁠Saliva: Do not eat, drink, smoke or chew gum for 30 minutes before collection. Buccal swab: Please refer to user instructions provided with kit. Ensure the sponge tip does not come into contact with any surface prior to collection. Do not eat, drink, smoke, or chew gum for 30 minutes before collection. Do not touch swab tips or allow contact with any other object.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

2 mL saliva to "fill to" line collected in OGD-500, Oragene-Dx Collection Kit or 1 buccal swab submitted in OCD-100A buccal kit (ORAcollect-Dx Collection Kit) or 10 mg skin fibroblasts collected in sterile plastic container or 2 flasks skin fibroblasts, cultured amniocytes or cultured chorionic villi collected in each of two separate sterile T25 culture flasks or 10 mL amniotic fluid collected in sterile plastic leak-proof container or 10 mg chorionic villi collected in a sterile tube filled with sterile culture media

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation