Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Cardio IQ® Myeloperoxidase (MPO)

Cardio IQ® Myeloperoxidase (MPO): Quest Diagnostics test 92814

Quest Diagnostics test 92814, CPT 83876. Specimen: 1 mL plasma collected in an EDTA (lavender-top) tube.

Cardio IQ® Myeloperoxidase (MPO) is Quest Diagnostics test code 92814, billed with CPT 83876. Specimen: 1 mL plasma collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code92814
CPT83876
LOINC—
Specimen1 mL plasma collected in an EDTA (lavender-top) tube
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportRefrigerated (cold packs)

Also known as: CardioIQ®

Methodology

Turbidimetric Immunoassay

Collection instructions

1. Draw and gently invert 8 to 10 times. 2. Centrifuge immediately for 10 minutes at 1300 RCF at room temperature. 3. Pre-squeeze transfer pipet bulb and draw off approximately 2/3 of the upper plasma layer. Note: This ensures that the buffy coat and red cells remain undisturbed. 4. Aliquot plasma into labeled transport tube labeled as “EDTA plasma and cap tightly. Discard original tube. 5. Store transport tube refrigerated at 2-8°C until ready to ship. Store plasma at 2-8°C after collection and ship the same day per packaging instructions provided with the Cleveland HeartLab, Inc. shipping box. Erratic results can be observed if plasma is not centrifuged and separated from red cells immediately.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated8 days
Frozen6 months

Causes for rejection

Gross hemolysis • Samples other than EDTA plasma including PPT potassium EDTA (white-top) tube • Improper labeling • Samples not stored properly • Samples older than stability limits

Reference range

<470 pmol/L

Assay category

The test was developed and its performance characteristics determined by Cleveland HeartLab, Inc. It has not been cleared or approved by the U.S. FDA. The laboratory is regulated under CLIA as qualified to perform high-complexity testing. This test is used for clinical purposes. It should not be regarded as investigational or for research.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 83876

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation