Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Factor VIII Antigen

Factor VIII Antigen: Quest Diagnostics test 90879

Quest Diagnostics test 90879, CPT 85244. Specimen: 1 mL frozen platelet-poor plasma collected in a 3.2% sodium citrate (light blue-top) tube.

Factor VIII Antigen is Quest Diagnostics test code 90879, billed with CPT 85244. Specimen: 1 mL frozen platelet-poor plasma collected in a 3.2% sodium citrate (light blue-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code90879
CPT85244
LOINC—
Specimen1 mL frozen platelet-poor plasma collected in a 3.2% sodium citrate (light blue-top) tube
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportFrozen

Methodology

Immunoassay (IA)

Collection instructions

Platelet-poor plasma: Centrifuge light blue-top tube for 15 minutes at approximately 1500 g within 60 minutes of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic screw-cap vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic screw-cap vial. Plasma must be free of platelets (<10, 000/mcl). Freeze immediately and ship on dry ice.

Stability

TemperaturePeriod
Room temperature4 hours
Refrigerated48 hours
Frozen -20° C30 days
Frozen -70° C6 months

Causes for rejection

Received room temperature • Received refrigerated

Reference range

0.60-1.95 IU/mL

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation