Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Industrial Cadmium Screen

Industrial Cadmium Screen: Quest Diagnostics test 8887

Quest Diagnostics test 8887, CPT 82232, 82300, 82570. Specimen: 4 mL whole blood collected in an EDTA (royal blue-top) tube or sodium heparin (royal blue-top) tube and.

Industrial Cadmium Screen is Quest Diagnostics test code 8887, billed with CPT 82232, 82300, 82570. Specimen: 4 mL whole blood collected in an EDTA (royal blue-top) tube or sodium heparin (royal blue-top) tube and. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Allina Health Laboratory (Abbott Northwestern), Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code8887
CPT82232, 82300 (x2), 82570
LOINC—
Specimen4 mL whole blood collected in an EDTA (royal blue-top) tube or sodium heparin (royal blue-top) tube and 7 mL random urine collected in an acid-washed or metal-free container and 10 mL random urine collected in a Quest Diagnostics Beta-2 Microglobulin Transport tube (available through Client Supply)
Minimum volume2 mL whole blood • 3 mL urine in an acid-washed or metal-free container • 10 mL urine in Beta-2 Microglobulin tube
Container⁠⁠⁠⁠⁠⁠⁠Whole blood: EDTA or sodium heparin (royal blue-top) tube Random urine: Acid-washed plastic urine container Random urine: Beta-2 Microglobulin Transport tube
Storage / transportRefrigerated (cold packs)

Also known as: Cadmium Industrial Screen

Methodology

Colorimetric (C) • Inductively Coupled Plasma/Mass Spectrometry (ICP/MS) • Kinetic • Nephelometry

Collection instructions

Three separate collections are required. One collection of blood and two separate collections of urine. Specimen 1: One EDTA (royal blue-top) tube or sodium heparin (royal blue-top) tube of whole blood. Specimen 2: For urine cadmium and creatinine: Collect urine in an acid-washed or metal-free plastic container. Label as Cadmium/Creatinine. Specimen 3: Once patient has voided bladder for cadmium/creatinine collection, 1. Patient should void bladder, then drink at least 500 mL (approximately 17 oz) of water. 2. A urine sample should be collected within 1 hour. 3. Pour exactly 10 mL of random urine into a Quest Diagnostics Beta-2 Microglobulin Transport Tube (#179979 available through Client Supply). 4. Ship refrigerated. 5. Alternatively, if the collection tubes are not available, pH the specimen to between 6 and 8 using 1N NaOH prior to shipping. Beta-2 Microglobulin in urine is unstable in acidic urine (less than pH 6). Exactly 10 mL of urine in the Quest Diagnostics Beta-2 Microglobulin Transport Tube is required to achieve the required pH of between 6 and 8. Any volume above or below 10 mL will result in a pH that is outside the acceptable range.

Stability

Whole blood Room temperature: 48 hours Refrigerated: 5 days Frozen: Unacceptable Cadmiun & Creatinine Urine Room temperature: 8 hours Refrigerated: 7 days Frozen: 14 days Beta-2 Microglobulin Urine Room temperature: 5 days Refrigerated: 15 days Frozen: 30 days

Causes for rejection

Beta-2 Microglobulin: Specimens received in a non-Beta-2 Microglobulin transport tube with a pH <6 • Any volume other than 10 mL urine in the transport tube • Any specimen with pH <6

Reference range

See individual tests

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82232, 82300, 82570

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation