Adenovirus Antigen, DFA: Quest Diagnostics test 8355

Quest Diagnostics test 8355, CPT 87260. Specimen: 3 mL nasopharyngeal aspirate/wash or nasopharyngeal swab in VCM medium or equivalent.

Adenovirus Antigen, DFA is Quest Diagnostics test code 8355, billed with CPT 87260. Specimen: 3 mL nasopharyngeal aspirate/wash or nasopharyngeal swab in VCM medium or equivalent. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code8355
CPT87260
LOINC—
Specimen3 mL nasopharyngeal aspirate/wash or nasopharyngeal swab in VCM medium or equivalent
Minimum volume1 mL
ContainerVCM medium tube or equivalent
Storage / transportRefrigerated (cold packs)

Also known as: Adenovirus Direct Antigen Detection; Adenovirus Direct Exam

Methodology

Direct Immunofluorescence Assay (DFA)

Collection instructions

To maintain optimum viability, place swab or fluid into VCM (equal volumes of fluid and VCM) or equivalent and transport the specimen to the laboratory as soon as possible. Best recovery is obtained when the specimens are refrigerated at 2-8° C or kept on wet ice following collection and while in transit. If there will be a long delay before processing, specimens in VCM or equivalent should be frozen at -70° C or colder and transported on dry ice. Storage or transport at -20° C is not acceptable.

Stability

VCM medium tube or equivalent Room temperature: Unacceptable Refrigerated: 4 days Frozen -20° C: Unacceptable Frozen -70° C: 30 days

Causes for rejection

Dry swabs • Nasal smear • Non-respiratory specimens • Received in formalin or other fixatives • Received in non-viral transport medium such as nucleic acid or bacterial transport media • Sputum • Throat swabs • Unpreserved samples

Reference range

See Laboratory Report

Alternative specimen(s)

3 mL bronchial lavage/wash in VCM medium or equivalent

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87260

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation