Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Antibody Screen, RBC with Reflex to Identification, Titer, and Antigen Typing

Antibody Screen, RBC with Reflex to Identification, Titer, and Antigen Typing: Quest Diagnostics test 795

Quest Diagnostics test 795, CPT 86850. Specimen: 5 mL whole blood collected in an EDTA (pink-top) tube.

Antibody Screen, RBC with Reflex to Identification, Titer, and Antigen Typing is Quest Diagnostics test code 795, billed with CPT 86850. Specimen: 5 mL whole blood collected in an EDTA (pink-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code795
CPT86850
LOINC—
Specimen5 mL whole blood collected in an EDTA (pink-top) tube
Minimum volume5 mL Collection instructions If submitting with a CBC, HbA1c, or any other test requiring an EDTA (lavender-top) tube, please submit a separate tube for this test
ContainerEDTA (pink-top) tube
Storage / transportRoom temperature

Also known as: RBC Antibody Screen

Methodology

Immune Agglutination

Stability

TemperaturePeriod
Room temperature72 hours
Refrigerated7 days
FrozenUnacceptable

Causes for rejection

Gross hemolysis • Serum separator tube (SST) • Spun red-top tube (no gel)

Reference range

No antibodies detected

Alternative specimen(s)

ACD (yellow-top) tube • Red-top tube (unspun no gel) • Cord blood • EDTA (lavender-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86850

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation