Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Cholesterol and HDL Cholesterol with Ratio

Cholesterol and HDL Cholesterol with Ratio: Quest Diagnostics test 7432

Quest Diagnostics test 7432, CPT 82465, 83718. Specimen: 1 mL serum.

Cholesterol and HDL Cholesterol with Ratio is Quest Diagnostics test code 7432, billed with CPT 82465, 83718. Specimen: 1 mL serum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Allina Health Laboratory (Abbott Northwestern).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code7432
CPT82465, 83718
LOINC—
Specimen1 mL serum
Minimum volume0.5 mL
ContainerTransport tube
Storage / transportRoom temperature

Methodology

Spectrophotometry (SP)

Collection instructions

Centrifuge within 30-60 minutes following collection

Stability

Serum Room temperature: 48 hours Refrigerated: 7 days Frozen: 28 days Plasma Room temperature: 48 hours Refrigerated: 48 hours Frozen: 28 days

Patient preparation

If a cholesterol measurement is to be performed along with triglycerides, the patient should be fasting 9-12 hours prior to collection. The assay manufacturer Beckman Coulter advises: "N-Acetyl Cysteine (NAC), when administered in therapeutic concentrations (for the treatment of acetaminophen overdose), has been. . . determined to interfere with assays for. . . cholesterol, uric acid" where "NAC interference may lead to falsely low results." According to Beckman Coulter, the NAC interference should be insignificant by 12 hours after completion of the initial loading dose of an IV infusion treatment regimen consisting of an initial loading dose of 150 mg/kg administered over 1 hour, a second dose of 50 mg/kg administered over 4 hrs and a third dose of 100 mg/kg administered over 16 hrs.

Causes for rejection

Gross hemolysis • Moderate to gross icterus • Anticoagulants other than heparin

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Alternative specimen(s)

Plasma collected in: Sodium heparin (green-top) tube or lithium heparin (green-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82465, 83718

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation