Quest Diagnostics test 58792, CPT 87385. Specimen: 0.5 mL urine collected in a sterile leak-proof container.

MVista® Histoplasma Antigen Quantitative EIA is Quest Diagnostics test code 58792, billed with CPT 87385. Specimen: 0.5 mL urine collected in a sterile leak-proof container. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code58792
CPT87385
LOINC—
Specimen0.5 mL urine collected in a sterile leak-proof container
Minimum volumeUrine, BAL or other body fluids: 0.5 mL CSF: 0.8 mL Serum or plasma: 1.2 mL Collection instructions Indicate specimen type and date drawn on test requisition. Two unique patient identifiers required on specimen container. Ship to arrive Monday-Friday using a next day delivery service or 2nd day service. Do not ship by first class mail. List all antifungal agents patient is receiving. Serum: Collect serum specimens in serum separator or red top tube. Allow blood to clot for 30 minutes, then centrifuge. Pipette serum into a plastic, screw-cap vial. Plasma: Collect plasma specimens in an EDTA, heparin or sodium citrate tube. Centrifuge for 15 minutes and pipette plasma into a plastic, screw-cap vial. Urine/CSF/BAL/other body fluid: Submit urine, CSF, BAL and all other body fluids in a sterile, screw-cap container. Note: Interfering substances and cross-reactivities include sodium hydroxide and sputolysin. Cross-reactivity occurs between blastomycosis and histoplasmosis and in paracoccidioidomycosis, penicillosis, coccidioidomycosis, aspergillosis and sporotrichosis.
ContainerSterile leak-proof container
Storage / transportRoom temperature

Methodology

Quantitative Sandwich Enzyme Immunoassay

Stability

TemperaturePeriod
Room temperature14 days
Refrigerated14 days
FrozenIndefinite

Causes for rejection

Stored in transport media • Tissue • Sputum • Bronchial brushings • Stool • Fine needle aspiration • Biopsy • Tracheal or bone marrow aspirate • Fixative or isolator tubes • If specimen is too viscous to pipette

Reference range

See Laboratory Report

Assay category

This test was developed and its performance characteristics determined by MiraVista Diagnostics. It has not been cleared or approved by the FDA; however, FDA clearance or approval is not currently required for clinical use. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions.

Alternative specimen(s)

1.2 mL plasma collected in an EDTA (lavender-top) tube, sodium heparin (green-top) tube, or 3.2% sodium citrate (light blue-top) tube • 1.2 mL serum • 0.8 mL CSF submitted in a sterile, leak-proof container • 0.5 mL bronchoalveolar lavage or body fluid submitted in a sterile, leak-proof container

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87385

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation