Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Platelet Antibody, Direct, Flow Cytometry

Platelet Antibody, Direct, Flow Cytometry: Quest Diagnostics test 5019

Quest Diagnostics test 5019, CPT 86023. Specimen: Whole blood collected in an EDTA (lavender-top) tube.

Platelet Antibody, Direct, Flow Cytometry is Quest Diagnostics test code 5019, billed with CPT 86023. Specimen: Whole blood collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code5019
CPT86023
LOINC—
SpecimenWhole blood collected in an EDTA (lavender-top) tube
Minimum volumeSee Collection Instructions
ContainerEDTA (lavender-top) tube
Storage / transportRoom temperature

Also known as: Anti-Platelet Antibody; Direct; Platelet Associated IgG; Flow; Platelet Bound Antibody

Methodology

Flow Cytometry (FC)

Collection instructions

Do not refrigerate or freeze. Effective 11/01/96, specimens submitted in ACD tubes (yellow-top) will no longer be accepted because of the high incidence of platelet clumping associated with this anticoagulant. If the platelet count is less than 20,000/ccm, submit 7-10 mL of whole blood. ⁠⁠⁠⁠⁠⁠⁠

Stability

TemperaturePeriod
Room temperature6 days
RefrigeratedUnacceptable
FrozenUnacceptable

Causes for rejection

Gross hemolysis • ACD tubes

≤20,000

10 mL Pediatric minimum volume: The minimum volume is platelet count dependent. If possible, submit at least 1 mL EDTA blood.

≥45,000

2 mL

20,000-45,000

4 mL

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes. This test is not available for New York patient testing.

Platelet Count

Minimum Volume

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86023

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation