Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Culture, Sputum/Lower Respiratory

Culture, Sputum/Lower Respiratory: Quest Diagnostics test 4556

Quest Diagnostics test 4556, CPT 87070, 87205. Specimen: 3-5 mL sputum.

Culture, Sputum/Lower Respiratory is Quest Diagnostics test code 4556, billed with CPT 87070, 87205. Specimen: 3-5 mL sputum. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Allina Health Laboratory (Abbott Northwestern), Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code4556
CPT87070, 87205
LOINC—
Specimen3-5 mL sputum
ContainerSterile leak-proof screw-cap container
Storage / transportRefrigerated (cold packs)

Also known as: Respiratory Culture; Lower Respiratory; Sputum Bacterial Culture

Methodology

Aerobic bacterial culture. Includes gram stain evaluation of specimen, routine isolation and identification procedures. Antibiotic susceptibility testing when appropriate.

Collection instructions

Early morning expectorated sputum from deep cough

Stability

Deliver to the Microbiology lab ASAP Room temperature: 2 hours maximum, then refrigerate ASAP Refrigerated: 24 hours Frozen: Unacceptable

Causes for rejection

Any specimen >48 hours old • 24-hour pooled sputum • Sputum received for anaerobic culture • Room temperature specimens 2 hours or older • Specimens which have leaked and contaminated the outside of the collection container • Sputum specimens with >25 epithelial cells per low power field • Received frozen Refrigerated specimens older than 24 hours but less than 48 hours old may be processed only after contacting the client and informing them that the results may be compromised. If they still desire the specimen cultured, medical director approval must be obtained and documented.

Reference range

See Laboratory Report

Notices

Not offered in Quest Diagnostics Nichols Institute (IFD) – San Juan Capistrano | Quest Nichols Institute -San Juan Capistrano, CA. Please provide Service area information to confirm Test Code for the lab that services your account or to find available tests you can order.

Alternative specimen(s)

5-10 mL bronchial wash or tracheal aspiration

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87070, 87205

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation