Borrelia burgdorferi DNA, Qualitative Real-Time PCR, Miscellaneous: Quest Diagnostics test 39209
Quest Diagnostics test 39209, CPT 87476. Specimen: 3 mL whole blood collected in an EDTA (lavender-top) tube or.
Borrelia burgdorferi DNA, Qualitative Real-Time PCR, Miscellaneous is Quest Diagnostics test code 39209, billed with CPT 87476. Specimen: 3 mL whole blood collected in an EDTA (lavender-top) tube or. Performing laboratory: Quest Diagnostics, CLIA
49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp.
Test code39209
CPT87476
LOINC—
Specimen3 mL whole blood collected in an EDTA (lavender-top) tube or
3 mL CSF or synovial fluid collected in a sterile plastic leak-proof container
Minimum volume0.5 mL
ContainerWhole blood: EDTA (lavender-top) tube
CSF or synovial fluid: Sterile leak-proof container
Storage / transportRefrigerated (cold packs)
Specimen stability
Whole blood
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days
CSF or synovial fluid
Room temperature: 48 hours
Refrigerated: 7 days
Frozen: 30 days
Also known as: Lyme; Tick borne
Methodology
Real-Time Polymerase Chain Reaction
Causes for rejection
Lithium heparin (green-top) tube • Sodium heparin (green-top) tube
Reference range
Not detected
Assay category
This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.
Alternative specimen(s)
Whole blood collected in: ACD (yellow-top) tube
View this test on Quest Diagnostics's website → · Last checked 2026-11-29
Other tests billed with CPT 87476
Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.