Hereditary Breast Cancer Panel: Quest Diagnostics test 38621

Quest Diagnostics test 38621, CPT 81432. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) or ACD (yellow-top) tube.

Hereditary Breast Cancer Panel is Quest Diagnostics test code 38621, billed with CPT 81432. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) or ACD (yellow-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services, Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code38621
CPT81432 Confirmation of Patient Informed Consent for Genetic Testing This genetic test requires provider confirmation that patient informed consent has been received if the ordering provider is located in AK, AZ, DE, FL, GA, IA, MA, MN, MT, NV, NH, NJ, NY, OR, SC, SD, or VT or testing is performed in
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) or ACD (yellow-top) tube
Minimum volume2 mL whole blood • 2 mL saliva • 1 buccal swab • 10 mg skin fibroblasts • 2 flasks 75% confluent
ContainerEDTA (lavender-top) tube or ACD (yellow-top) tube
Storage / transportRoom temperature

Also known as: Familial; Multi-Gene Cancer; BRCA; Li-Fraumeni syndrome; Cowden syndrome; HBOC; BRACA; BRCA1/2; CHECK2; HNPCC; Lynch Syndrome; Inherited Cancer Panel; Cancer Genes; Hereditary Cancer

Methodology

DNA Bait Capture • Long Range Polymerase Chain Reaction • Next Generation Sequencing • Microarray

Collection instructions

Do not hold specimen. Forward to laboratory when specimen arrives. Whole blood: Normal phlebotomy procedure. Specimen stability is crucial. Store and ship room temperature immediately. Do not freeze. Saliva: 2 mL saliva collected in the Oragene-Dx collection kit up to the "fill to" line (OGD-500/OGD-600, OGD-510/OGD-610). Do not remove the plastic film from the funnel lid. For fibroblasts and skin fibroblasts, call 1-866-GENEINFO (1-866-436-3463) prior to collecting and ordering.

Stability

Whole blood Room temperature: 14 days Refrigerated: 14 days Frozen: Unacceptable Saliva or buccal swab Room temperature: 14 days Refrigerated: 14 days Frozen: 14 days Fibroblasts and skin fibroblasts Room temperature: 48 hours Refrigerated: Unacceptable Frozen: Unacceptable

Patient preparation

Saliva: Do not eat, drink, smoke or chew gum for 30 minutes before collection. Buccal swab: Please refer to user instructions provided with kit. Ensure the sponge tip does not come into contact with any surface prior to collection. Do not eat, drink, smoke, or chew gum for 30 minutes before collection. Do not touch swab tips or allow contact with any other object.

Causes for rejection

Do not reject. Forward to performing laboratory for evaluation of sample.

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

2 mL saliva to "fill to" line collected in OGD-500, Oragene-Dx Collection Kit or 1 buccal swab submitted in OCD-100A buccal kit (ORAcollect-Dx Collection Kit) or 10 mg skin fibroblasts collected in sterile plastic container or 2 flasks skin fibroblasts collected in each of two separate sterile T25 culture flasks or equivalent with 80-100% confluent growth

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81432

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation