Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Heavy Metals Panel, 24-Hour Urine

Heavy Metals Panel, 24-Hour Urine: Quest Diagnostics test 36438

Quest Diagnostics test 36438, CPT 82175, 83655, 83825. Specimen: 7 mL aliquot of a well-mixed 24-hour urine collected in an acid-washed or metal-free container.

Heavy Metals Panel, 24-Hour Urine is Quest Diagnostics test code 36438, billed with CPT 82175, 83655, 83825. Specimen: 7 mL aliquot of a well-mixed 24-hour urine collected in an acid-washed or metal-free container. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs), Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code36438
CPT82175, 83655, 83825
LOINC—
Specimen7 mL aliquot of a well-mixed 24-hour urine collected in an acid-washed or metal-free container
Minimum volume3 mL
ContainerAcid-washed plastic urine container
Storage / transportRefrigerated (cold packs)

Methodology

Inductively Coupled Plasma/Mass Spectrometry (ICP/MS)

Collection instructions

Avoid worksite collection. Collect urine in an acid-washed or metal-free plastic container.

Stability

TemperaturePeriod
Room temperature48 hours
Refrigerated5 days
Frozen14 days

Patient preparation

Avoid seafood consumption for 48 hours prior to collection

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Tests performed on a specimen submitted in a non-trace element tube or non acid-washed/non metal-free container may not accurately reflect the patient's level.  If a non-trace element tube/container is received, it will be accepted for testing. However, elevated results shall be reported with a message that re-submission with a trace element tube/container is recommended.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82175, 83655, 83825

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation