Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Factor II Activity, Clotting

Factor II Activity, Clotting: Quest Diagnostics test 331

Quest Diagnostics test 331, CPT 85210. Specimen: 1 mL frozen platelet-poor plasma collected in 3.2% sodium citrate (light blue-top) tube.

Factor II Activity, Clotting is Quest Diagnostics test code 331, billed with CPT 85210. Specimen: 1 mL frozen platelet-poor plasma collected in 3.2% sodium citrate (light blue-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), Labcorp, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code331
CPT85210
LOINC—
Specimen1 mL frozen platelet-poor plasma collected in 3.2% sodium citrate (light blue-top) tube
Minimum volume0.5 mL Collection instructions Please submit a separate, frozen vial for each special coagulation assay ordered. Draw blood in a light blue-top tube containing 3.2% sodium citrate, mix gently by inverting 3-4 times. Centrifuge 15 minutes at 1500 g within one hour of collection. Using a plastic pipette, remove plasma, taking care to avoid the WBC/platelet buffy layer and place into a plastic vial. Centrifuge a second time and transfer platelet-poor plasma into a new plastic vial(s). Freeze immediately and transport on dry ice.
ContainerTransport tube
Storage / transportFrozen

Also known as: Factor II Functional; Coag Factor II Activity; Prothrombin

Methodology

Photometric Clot Detection

Stability

TemperaturePeriod
Room temperatureUnacceptable
RefrigeratedUnacceptable
Frozen28 days

Causes for rejection

Hemolysis • Received thawed

Reference range

70-150 % normal

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 85210

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation