Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Acanthamoeba/Naegleria Culture

Acanthamoeba/Naegleria Culture: Quest Diagnostics test 23086

Quest Diagnostics test 23086, CPT 87081. Specimen: 1 mL CSF collected in a CSF collection tube or 3 mm biopsy,scraping or equivalent tissue from brain, lung, cornea, or le.

Acanthamoeba/Naegleria Culture is Quest Diagnostics test code 23086, billed with CPT 87081. Specimen: 1 mL CSF collected in a CSF collection tube or 3 mm biopsy,scraping or equivalent tissue from brain, lung, cornea, or lesion collected in a . Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code23086
CPT87081
LOINC—
Specimen1 mL CSF collected in a CSF collection tube or 3 mm biopsy,scraping or equivalent tissue from brain, lung, cornea, or lesion collected in a sterile container with 2 mL sterile saline or 1 sterile swab of conjunctiva/corneal ulcer collected in a sterile container with 2 mL of sterile saline or 2 contact lenses suspended in 2 mL lens care solution from an open container (already in use by patient) or in 2 mL sterile saline collected in a sterile, leak-proof container
Minimum volume0.5 mL CSF or 1 contact lens
ContainerSterile container with 2 mL sterile saline CSF collection container
Storage / transportRoom temperature

Methodology

Culture

Collection instructions

All specimens should be collected aseptically and held at room temperature (20-25° C). Do not freeze or refrigerate specimens. Do not dilute CSF or contact Lens Solution with sterile saline.

Stability

TemperaturePeriod
Room temperature7 days
RefrigeratedUnacceptable
FrozenUnacceptable

Causes for rejection

Liver fluid • Slides • Swabs in bacterial or viral transport medium

Reference range

Not isolated

Alternative specimen(s)

2 mL lens care solution from an open container (already in use by patient)

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87081

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation