Quest Diagnostics test 19826, CPT 82542. Specimen: 1 mL serum collected in a Serum separator tube (SST).

Coenzyme Q10 is Quest Diagnostics test code 19826, billed with CPT 82542. Specimen: 1 mL serum collected in a Serum separator tube (SST). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, Michigan Medicine Laboratories (MLabs), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code19826
CPT82542
LOINC—
Specimen1 mL serum collected in a Serum separator tube (SST)
Minimum volume0.3 mL
ContainerAmber transport tube
Storage / transportRefrigerated (cold packs)

Also known as: Ubiquinone; Coenzyme Q; Q10; Ubiquinol

Methodology

Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)

Collection instructions

It is preferred that the specimen is shipped the day it is drawn. Please wrap the specimen in foil or transfer specimens to amber tubes if they are not to be shipped the same day. Specimens must be protected from direct light. 1. Gently invert 5x (DO NOT SHAKE!). 2. Let blood clot for 30 minutes at room temperature. 3. Centrifuge for 10 minutes. 4. Store and transport refrigerated.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated14 days
Frozen6 weeks

Patient preparation

Fasting is not required. Patients should not take Coenzyme Q10 supplements the morning of the test. They may take other nutritional supplements prior to testing.

Causes for rejection

Samples that are not shipped the same day of collection if not protected from light exposure

Reference range

>0.35 ug/mL

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics Cardiometabolic Center of Excellence at Cleveland HeartLab. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82542

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation