Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Factor V HR2 Allele DNA Mutation Analysis

Factor V HR2 Allele DNA Mutation Analysis: Quest Diagnostics test 17902

Quest Diagnostics test 17902, CPT 81400. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube.

Factor V HR2 Allele DNA Mutation Analysis is Quest Diagnostics test code 17902, billed with CPT 81400. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code17902
CPT81400
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) tube Alternative specimen(s)
Minimum volume3 mL
ContainerEDTA (lavender-top) tube
Storage / transportRoom temperature

Methodology

Fluorescent Microshperes • Oligonucleotide Ligation Assay • Polymerase Chain Reaction (PCR)

Collection instructions

Whole blood: Normal phlebotomy procedure. Specimen stability is crucial. Store and ship ambient immediately. Do not freeze. For prenatal diagnosis with a fetal specimen: 1) parents must be documented carriers of one of the mutations tested. 2) maternal blood or DNA must be available 3) contact the laboratory genetic counselor before submission. Extracted DNA: Please call 1-(866)-GENE-INFO or 1-866-436-3463 for additional information. Frozen shipping is acceptable.

Stability

TemperaturePeriod
Room temperature8 days
Refrigerated8 days
Frozen30 days

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by the U.S. Food and Drug Administration. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81400

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation