Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › HLA Typing for Celiac Disease

HLA Typing for Celiac Disease: Quest Diagnostics test 17135

Quest Diagnostics test 17135, CPT 81376, 81382. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube.

HLA Typing for Celiac Disease is Quest Diagnostics test code 17135, billed with CPT 81376, 81382. Specimen: 5 mL whole blood collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Labcorp, Michigan Medicine Laboratories (MLabs), OHSU Laboratory Services, Cleveland Clinic Laboratories, ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code17135
CPT81382 (x2), 81376 (x2) CPT coding may differ dependent on payer rules which may impact prior authorization testing. Please direct any questions regarding CPT coding to the payer being billed.
LOINC—
Specimen5 mL whole blood collected in an EDTA (lavender-top) tube
Minimum volume3 mL
ContainerEDTA (lavender-top) tube
Storage / transportRoom temperature

Methodology

Polymerase Chain Reaction Amplification followed by Sequence Specific Oligonucleotide Probes (PCR-SSO)

Collection instructions

A separate EDTA (lavender-top) tube must be submitted for all HLA testing. If submitted with any other test requiring an EDTA tube, please submit a separate tube for this test. Do not open tube.

Stability

TemperaturePeriod
Room temperature7 days
Refrigerated7 days
FrozenUnacceptable

Causes for rejection

Received frozen • Clotted

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Alternative specimen(s)

Whole blood collected in: Sodium heparin (green-top) tube, EDTA (pink-top) tube, EDTA (royal blue-top) tube, or 3.2% sodium citrate (light blue-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81376, 81382

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation