Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › ColoVantage® (Methylated Septin 9)

ColoVantage® (Methylated Septin 9): Quest Diagnostics test 16983

Quest Diagnostics test 16983, CPT 81327. Specimen: 10 mL frozen plasma collected in an EDTA (lavender-top) tube.

ColoVantage® (Methylated Septin 9) is Quest Diagnostics test code 16983, billed with CPT 81327. Specimen: 10 mL frozen plasma collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16983
CPT81327
LOINC—
Specimen10 mL frozen plasma collected in an EDTA (lavender-top) tube
Minimum volume5 mL
ContainerTransport tube(s)
Storage / transportFrozen

Methodology

Real-Time Polymerase Chain Reaction

Collection instructions

This test requires 10 mL of plasma (minimum volume 5 mL). Specimens with less than 5 mL of plasma will be rejected. To obtain this volume of plasma, collect blood in two (2) 10 mL EDTA (lavender-top) tubes or five (5) standard EDTA (lavender-top) tubes. Centrifuge the blood samples, separate plasma and combine them within 4 hours of collection. Failure to do so may result in a false negative result. Send plasma in a single 10 mL pour-off tube. If a 10 mL pour-off tube is not available, two (2) 5 mL pour-off tubes can be used.

Stability

TemperaturePeriod
Room temperatureUnacceptable
RefrigeratedUnacceptable
Frozen28 days

Causes for rejection

Received room temperature • Received refrigerated • Less than 5 mL of specimen

Reference range

Not detected

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes. This test code is for non-New York patient testing. For New York patient testing, use test code 16984.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.