Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Catecholamines, Fractionated, Upright, Plasma

Catecholamines, Fractionated, Upright, Plasma: Quest Diagnostics test 16382

Quest Diagnostics test 16382, CPT 82384. Specimen: 2 mL frozen plasma collected in a sodium heparin (green-top) tube.

Catecholamines, Fractionated, Upright, Plasma is Quest Diagnostics test code 16382, billed with CPT 82384. Specimen: 2 mL frozen plasma collected in a sodium heparin (green-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Labcorp, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16382
CPT82384
LOINC—
Specimen2 mL frozen plasma collected in a sodium heparin (green-top) tube
Minimum volume1 mL
ContainerTransport tube
Storage / transportFrozen

Methodology

Liquid Chromatography/Mass Spectrometry (LC/MS)

Collection instructions

Draw specimen in a pre-chilled green-top vacutainer. Plasma should be separated in a refrigerated centrifuge within 30 minutes of collection and then frozen immediately at -20° C in plastic vials. Each specimen will be invoiced separately.

Stability

TemperaturePeriod
Room temperature6 hours
Refrigerated6 hours
Frozen30 days

Patient preparation

Overnight fasting is preferred. Patients should be relaxed in an upright position before blood is drawn. States of anxiety and stress can cause fluctuations in the catecholamine levels. Patient should avoid alcohol, coffee, tea, tobacco and strenuous exercise prior to collection.

Causes for rejection

Received room temperature • Received refrigerated

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Frozen plasma collected in: EDTA (lavender-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82384

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation