Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Clostridium difficile Toxin B, Qualitative, Real-Time PCR

Clostridium difficile Toxin B, Qualitative, Real-Time PCR: Quest Diagnostics test 16377

Quest Diagnostics test 16377, CPT 87493. Specimen: 5 mL unpreserved stool collected in a sterile leak-proof container..

Clostridium difficile Toxin B, Qualitative, Real-Time PCR is Quest Diagnostics test code 16377, billed with CPT 87493. Specimen: 5 mL unpreserved stool collected in a sterile leak-proof container.. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: OHSU Laboratory Services, Labcorp, Allina Health Laboratory (Abbott Northwestern), ARUP Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16377
CPT87493
LOINC—
Specimen5 mL unpreserved stool collected in a sterile leak-proof container.
Minimum volume1 mL
ContainerSterile leak-proof container
Storage / transportFrozen

Also known as: C. difficile Toxin B Gene

Methodology

Real-Time Polymerase Chain Reaction

Collection instructions

Transfer liquid or soft stool (but not urine) into the container. Avoid mixing toilet paper, or soap with the sample. Store sample refrigerated until shipment.

Stability

TemperaturePeriod
Room temperatureUnacceptable
Refrigerated5 days
Frozen30 days

Causes for rejection

Specimen other than liquid or semi-formed stool • Stool in preservative or mixed with urine • Specimen in wrong transport container

Reference range

Not detected

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87493

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation