Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Campylobacter species Antigen, EIA

Campylobacter species Antigen, EIA: Quest Diagnostics test 16302

Quest Diagnostics test 16302, CPT 87449. Specimen: 10 grams stool submitted in Cary-Blair stool culture transport medium.

Campylobacter species Antigen, EIA is Quest Diagnostics test code 16302, billed with CPT 87449. Specimen: 10 grams stool submitted in Cary-Blair stool culture transport medium. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Allina Health Laboratory (Abbott Northwestern), Labcorp.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code16302
CPT87449
LOINC—
Specimen10 grams stool submitted in Cary-Blair stool culture transport medium
Minimum volume5 grams
ContainerCary-Blair stool culture transport medium
Storage / transportRoom temperature

Also known as: Campy ELISA; Campy Antigen Detection; Campy EIA

Methodology

Immunoassay (IA)

Stability

TemperaturePeriod
Room temperature4 days
Refrigerated4 days
FrozenUnacceptable

Causes for rejection

Unpreserved at any temperature • Stool specimens preserved in medium other than those listed • Stool specimens that have been previously concentrated • Specimens in diapers

Reference range

Not detected

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 87449

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation