Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Chronic Lymphocytic Leukemia, IgVH Mutation Status

Chronic Lymphocytic Leukemia, IgVH Mutation Status: Quest Diagnostics test 15480

Quest Diagnostics test 15480, CPT 81263. Specimen: 5 mL whole blood or 3 mL bone marrow aspirate collected in an EDTA (lavender-top) tube.

Chronic Lymphocytic Leukemia, IgVH Mutation Status is Quest Diagnostics test code 15480, billed with CPT 81263. Specimen: 5 mL whole blood or 3 mL bone marrow aspirate collected in an EDTA (lavender-top) tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), ARUP Laboratories, Labcorp, Cleveland Clinic Laboratories.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code15480
CPT81263
LOINC—
Specimen5 mL whole blood or 3 mL bone marrow aspirate collected in an EDTA (lavender-top) tube
Minimum volume3 mL whole blood • 1 mL bone marrow aspirate
ContainerEDTA (lavender-top) tube
Storage / transportRefrigerated (cold packs)

Also known as: Immunoglobulin VH Gene Mutation; IgVH Mutation Analysis; CLL; Next Generation Sequencing; NGS

Methodology

Next Generation Sequencing (NGS)

Collection instructions

Do not reject specimens, send to laboratory for screening. Whole blood collected in PPT-Potassium EDTA (white-top) tubes is unacceptable. Whole blood or bone marrow is shipped refrigerated. Do not freeze whole blood or bone marrow. After collection of the sample, draw date and time, as well as sample type, must be written on the tube and included as requested information. Ship sample immediately due to short sample stability of 72 hours. If the stability of the sample cannot be determined, delay in result of cancellation of test may occur. Alternative samples: FROZEN CELLS must be approved by the medical director before sending. Do not thaw. Must remain frozen until testing. Stability restrictions: Recommend samples arrive Monday through Friday a.m. within 24 hours of collection.

Stability

TemperaturePeriod
Room temperature72 hours
Refrigerated72 hours
FrozenUnacceptable

Causes for rejection

Moderate hemolysis • Gross hemolysis • Lipemia

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

Alternative specimen(s)

Whole blood collected in: Sodium heparin (green-top) tube or ACD solution B (yellow-top) tube • Bone marrow aspirate collected in: Sodium heparin (green-top) tube

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 81263

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation