Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Chromosome Analysis and Alpha-Fetoprotein with Reflex to AchE and Fetal Hgb, Amniotic Fluid

Chromosome Analysis and Alpha-Fetoprotein with Reflex to AchE and Fetal Hgb, Amniotic Fluid: Quest Diagnostics test 14591

Quest Diagnostics test 14591, CPT 82106, 88235, 88267, 88280. Specimen: 20 mL amniotic fluid collected in a sterile screw-cap container.

Chromosome Analysis and Alpha-Fetoprotein with Reflex to AchE and Fetal Hgb, Amniotic Fluid is Quest Diagnostics test code 14591, billed with CPT 82106, 88235, 88267, 88280. Specimen: 20 mL amniotic fluid collected in a sterile screw-cap container. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Michigan Medicine Laboratories (MLabs), Labcorp, OHSU Laboratory Services.
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code14591
CPT88235, 88267, 88280, 82106
LOINC—
Specimen20 mL amniotic fluid collected in a sterile screw-cap container
Minimum volume5 mL
ContainerGenetics transport pack
Storage / transportRoom temperature

Methodology

Culture • Karyotype • Microscopy AFP: Immunoassay (IA) • Gel Electrophoresis • Immunodiffusion (ID)

Collection instructions

30 mL is preferred if other testing, e.g. microarray, FISH is ordered. Ship at room temperature. Do not freeze. Send all tubes to lab (supernatant for AFP will be split by cytogenetics lab). Please contact the laboratory Genetic Counselor at 1-866-GENEINFO (1-866-436-3463) with any questions.

Stability

TemperaturePeriod
Room temperaturePreferred
RefrigeratedAcceptable
FrozenUnacceptable

Causes for rejection

Received frozen

Reference range

See Laboratory Report

Notices

CPT Code is subject to a Medicare Limited Coverage Policy and may require a signed ABN when ordering.

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes. This test code is for non-New York patient testing. For New York patient testing, use test code 17851.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 82106, 88235, 88267

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation