Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Electron Microscopy

Electron Microscopy: Quest Diagnostics test 14249

Quest Diagnostics test 14249, CPT 88348. Specimen: Tissue submitted in buffered glutaraldehyde (2.5%-3%).

Electron Microscopy is Quest Diagnostics test code 14249, billed with CPT 88348. Specimen: Tissue submitted in buffered glutaraldehyde (2.5%-3%). Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, OHSU Laboratory Services, ARUP Laboratories, Michigan Medicine Laboratories (MLabs).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code14249
CPT88348
LOINC—
SpecimenTissue submitted in buffered glutaraldehyde (2.5%-3%)
ContainerTransport container
Storage / transport⁠⁠⁠⁠⁠⁠⁠Tissue: Room temperature FFPE: Refrigerated (cold packs) Specimen stability ⁠⁠⁠⁠⁠⁠⁠Tissue Room temperature: 1 year Refrigerated: 1 year Frozen: Unacceptable FFPE Room temperature: Acceptable Refrigerated: Preferred Frozen: Unacceptable Do not freeze. Do not reject.

Also known as: EM; Anatomic Pathology

Methodology

Microscopy

Collection instructions

Specimen: Kidney, muscle, nerve, cilia (brushing and biopsies). Immediately after removal of tissue, the specimen should be immersed in fixative. For samples other than listed, please contact the lab at 972-966-7207 1. Please provide patient information including: - Patient information (name, age, etc.) - Patient history or pathologist comments - Specimen type - Reason for testing - Type of fixative - Time and duration of fixation - Physician contact information 2. Indicate the patient's first and last name and include a second unique identifier on each of the vials. The name on the vials must match the paperwork being sent with the specimens. The specimen source and fixative used must be clearly marked on each vial. 3. For needle core biopsies, place directly into fixative. Avoid crushing tissue when handling. 4. For renal biopsies, specimen should be examined for the presence of glomeruli prior to submission to med fusion. Use sharp razor blade or scalpel to remove at least 1 mm cubes (2-3 glomeruli) from the ends of cores for EM. Larger samples should be sectioned into 1x1x1 mm strips before fixing. 5. For paraffin embedded tissue, the area of interest should be marked clearly on the microscopic slide corresponding to the block submitted for processing. The paraffin block and the slide should be labeled with the record number and patient name. 6. For ciliary brushing, immediately immerse the brush in fixative. The results of the ultrastructural evaluation are images that will be made available to physicians via the med fusion Client Collaboration Portal. Each site/physician will be given a unique address and log in credentials to access their images. Or the med fusion EM lab provides hard copies at the client's request. Note: Paraffin-embedded samples not accepted for cilia. Do not freeze. Do not reject.

Causes for rejection

Alternate fixatives • Improper fixation • Improper preparation • No fixative on specimen • Specimen not immersed in fixative • Tissue from cases of suspected transmissible spongiform encephalopathies (TSE), including Creutzfeldt-Jakob disease (CJD)

Reference range

See Laboratory Report

Assay category

This test is not available for New York patient testing.

Alternative specimen(s)

One (1) 10% neutral buffered formalin-fixed tissue or paraffin-embedded tissue

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 88348

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation