Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Quest Diagnostics › Complement Component C4a, Plasma

Complement Component C4a, Plasma: Quest Diagnostics test 13555

Quest Diagnostics test 13555, CPT 86160. Specimen: 2 mL frozen plasma collected in an EDTA (lavender-top) tube submitted in a protease inhibitor transport tube.

Complement Component C4a, Plasma is Quest Diagnostics test code 13555, billed with CPT 86160. Specimen: 2 mL frozen plasma collected in an EDTA (lavender-top) tube submitted in a protease inhibitor transport tube. Performing laboratory: Quest Diagnostics, CLIA 49D0221801 (Chantilly, VA). Other labs in the directory with tests billed under the same CPT: Michigan Medicine Laboratories (MLabs), Labcorp, ARUP Laboratories, Cleveland Clinic Laboratories, Allina Health Laboratory (Abbott Northwestern).
LaboratoryQuest Diagnostics
CLIA number49D0221801
Test code13555
CPT86160
LOINC—
Specimen2 mL frozen plasma collected in an EDTA (lavender-top) tube submitted in a protease inhibitor transport tube
Minimum volume1 mL
ContainerProtease inhibitor transport tube
Storage / transportFrozen

Also known as: C4a des Arg; C4a complement; Activation Complement C4a

Methodology

Enzyme Linked Immunosorbent Assay (ELISA)

Collection instructions

Collect whole blood into EDTA (lavender-top) tube. Centrifuge and pour 1-2 mL plasma carefully into protease inhibitor transport tube. (Note gradations on side of tube.) Freeze and transport on dry ice.

Stability

TemperaturePeriod
Room temperatureUnacceptable
RefrigeratedUnacceptable
Frozen -20° C21 days
Frozen -70° C60 days

Causes for rejection

Gross hemolysis • Grossly lipemic • Specimen not shipped in protease inhibitor transport tube • Grossly icteric

Reference range

≤1028 ng/mL

Assay category

This test was developed and its analytical performance characteristics have been determined by Quest Diagnostics. It has not been cleared or approved by FDA. This assay has been validated pursuant to the CLIA regulations and is used for clinical purposes.

View this test on Quest Diagnostics's website → · Last checked 2026-11-29

Other tests billed with CPT 86160

Search the National Lab Test Directory · All Quest Diagnostics tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation