Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Penn State Health Laboratories › Troponin T, High Sensitive

Troponin T, High Sensitive: Penn State Health Laboratories test TNT5

Penn State Health Laboratories test TNT5. Specimen: Lithium heparin plasma only. Turnaround: 1 hour.

Troponin T, High Sensitive is Penn State Health Laboratories test code TNT5. Specimen: Lithium heparin plasma only. Turnaround time: 1 hour. Performing laboratory: Penn State Health Laboratories, CLIA 39D0657304 (Hershey, PA).
LaboratoryPenn State Health Laboratories
CLIA number39D0657304
Test codeTNT5
CPT—
LOINC—
SpecimenLithium heparin plasma only
Turnaround time1 hour

Also known as: Troponin T (5th Gen) Powerchart: Troponin T

Stability

Stable for 24 hours at 2 - 8 degrees C, 12 months at -20 degrees C, freeze only once

Reference range

Reference Value: cTnT >52 ng/L: Myocardial necrosis present. This may be due to acute myocardial ischemia (AMI) or other myocardial injury. cTnT <14 ng/L (Females) or <20 ng/L (Males): 99th percentile upper reference limit for ostensibly healthy adult reference population. TNT5 Comment: To use the high-sensitivity cTnT assay, at least 2 blood samples should be drawn at time 0 and then at least 1h later. If the cTnT concentration at time 0 is ≥53 ng/L in a patient whose clinical presentation is consistent with acute coronary syndrome, then there is a high likelihood that acute myocardial injury is present. However, confirmation of acute myocardial injury still requires a second cTnT to be drawn. Delta cut-offs for determining the presence of acute myocardial injury have been validated at the 1-hour and 2-hour time points referenced here. A 1-hour delta troponin >5 ng/L indicates acute myocardial injury. A 2h delta troponin >7 ng/L indicates acute myocardial injury. Values below these are consistent with chronic myocardial injury. For patients where there is a high index of suspicion for acute coronary syndrome, repeating the tests at 1 or 2 hours, and calculating a new delta, may be indicated. If the second sample is collected in less than 60 minutes, no delta calculation will be performed. Deltas for blood samples drawn more than 3 hours apart have not been validated and will not be reported. Please interpret with caution. Delta Calculations: …

Section

Automated Testing Laboratory

Performed

7 days per week, 24 hours per day

Type Specimen

Lithium heparin plasma (green top tube)

Preferred Volume

Full green top tube

Fluid Type And Minimum Volume

1 mL plasma

View this test on Penn State Health Laboratories's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Penn State Health Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation