Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Penn State Health Laboratories › JAK2 V617F mutation

JAK2 V617F mutation: Penn State Health Laboratories test JAK2

Penn State Health Laboratories test JAK2. Turnaround: 7 days.

JAK2 V617F mutation is Penn State Health Laboratories test code JAK2. Turnaround time: 7 days. Performing laboratory: Penn State Health Laboratories, CLIA 39D0657304 (Hershey, PA).
LaboratoryPenn State Health Laboratories
CLIA number39D0657304
Test codeJAK2
CPT—
LOINC—
Volume3.0 mLs of whole blood or 0.5 ml Bone Marrow in a EDTA Lavender Top Tube
Minimum volume3 ml of Whole Blood 0.5 ml of Bone Marrow
ContainerWhole Blood or Bone Marrow in EDTA Lavender Top Tube
Turnaround time7 days
Storage / transportRoom Temperature, then Refrigerate

Also known as: JAK2 Tyrosine Kinase Val617Phe; Janus kinase 2 gene; Tyrosine kinase mutation; 83872-JAK2B

Collection instructions

Do not spin. Keep at room temperature until courier pickup

Patient preparation

None

Reference range

Accompanies report

Section

Molecular Diagnostics

Performed

24 hours day

Test Results

Negative or Positive for the JAK-2 V617F Mutation

Critical Value

Not applicable

Transport Time

Deliver to lab within 2 hours of specimen collection

Fluid Slash Tissue Type

Whole Blood Bone Marrow

Additional Test Information

Requires Hematology / Oncology Consult

Special Handling Instructions

Do not centrifuge

View this test on Penn State Health Laboratories's website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Penn State Health Laboratories tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation