Donor Specific Endothelial Cell Crossmatch: Michigan Medicine Laboratories (MLabs) test UECXM
Michigan Medicine Laboratories (MLabs) test UECXM. Specimen: Four ACD tubes from the Donor and One Red top tube from the recipient (HLA may have stored serum that can be used instea. Turnaround: 3 - 5 days.
Donor Specific Endothelial Cell Crossmatch is Michigan Medicine Laboratories (MLabs) test code UECXM. Specimen: Four ACD tubes from the Donor and One Red top tube from the recipient (HLA may have stored serum that can be used instead). Turnaround time: 3 - 5 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA
23D0366712 (Ann Arbor, MI).
Test codeUECXM
CPT—
LOINC—
SpecimenFour ACD tubes from the Donor and One Red top tube from the recipient (HLA may have stored serum that can be used instead)
VolumeFour ACD tubes from the Donor and One Red top tube from the recipient (HLA may have stored serum that can be used instead)
Turnaround time3 - 5 days
Storage / transportAmbient
Collection instructions
Collect specimen in four, ACD tubes, inquire if HLA has serum from one red top tube saved. Send/ have sent to Specimen Processing at room temperature.
Reference range
Interpretive report provided.
Section
Sendout Testing
Performed
Monday - Friday
Contraindications
The test is limited to cases in which antibody to donor HLA is not detectable in a flow cytometric crossmatch performed with lymphocyte targets.
NY State approved
No
Performing Laboratory
Sendout Testing
View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29
Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations
Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code.
Submit your lab's test menu → Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.
Book a free consultation