Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Adult Emergency Room Laboratory, Traumatic Brain Injury Acute Biomarkers

Adult Emergency Room Laboratory, Traumatic Brain Injury Acute Biomarkers: Michigan Medicine Laboratories (MLabs) test TRBI

Michigan Medicine Laboratories (MLabs) test TRBI. Specimen: 0.5 mL. Turnaround: 15-minute run time.

Adult Emergency Room Laboratory, Traumatic Brain Injury Acute Biomarkers is Michigan Medicine Laboratories (MLabs) test code TRBI. Specimen: 0.5 mL. Turnaround time: 15-minute run time. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeTRBI
CPT—
LOINC—
Specimen0.5 mL
Volume0.5 mL
Turnaround time15-minute run time
Storage / transportRefrigerated after testing

Also known as: TBI; GFAP; UCHL1; GFAP

Use

The i-STAT TBI test is a panel of in vitro diagnostic immunoassays for the quantitative measurements of glial fibrillary acidic protein (GFAP) and ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) in whole blood and a semi-quantitative interpretation of test results derived from these measurements, using the i-STAT Alinity instrument. The interpretation of test results is used, in conjunction with other clinical information, to aid in the evaluation of patients, 18 years of age or older, presenting with suspected mild traumatic brain injury (Glasgow Coma Scale score 13-15), which may include one of the following four clinical criteria: 1) any period of loss of consciousness 2) any loss of…

Collection instructions

Not Applicable

Reference range

GFAP <65 pg/mL UCH-L1 <360 pg/mL University of Michigan Guidelines for Using GFAP and UCH-L1 in Brain CT Imaging Decision-Making for Traumatic Brain Injury Evaluation

Limitations

• The i-STAT TBI test is not intended to be used as a stand-alone device but as an adjunct to other clinical information to aid in the evaluation of patients who are being considered for standard of care neuroimaging. • A ‘Not Elevated’ result is generally associated with the absence of acute intracranial lesions. An appropriate neuroimaging method is required for diagnosis of acute intracranial lesions. • Samples from patients who have been exposed to animals or who have received therapeutic or diagnostic procedures employing immunoglobulins or reagents derived from immunoglobulins may contain antibodies, e.g., HAMA or other heterophile antibodies, which may interfere with immunoassays and…

Section

Clinical Chemistry

Performed

Daily, 24 hours a day

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.