Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Serotonin Release Assay

Serotonin Release Assay: Michigan Medicine Laboratories (MLabs) test SRAU

Michigan Medicine Laboratories (MLabs) test SRAU, CPT 82542. Specimen: 1 mL serum AND full 2.7 mL tube or 1 mL plasma aliquot. Turnaround: 2 - 4 days.

Serotonin Release Assay is Michigan Medicine Laboratories (MLabs) test code SRAU, billed with CPT 82542. Specimen: 1 mL serum AND full 2.7 mL tube or 1 mL plasma aliquot. Turnaround time: 2 - 4 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Cleveland Clinic Laboratories, ARUP Laboratories, Quest Diagnostics.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeSRAU
CPT82542
LOINC—
Specimen1 mL serum AND full 2.7 mL tube or 1 mL plasma aliquot
Volume1 mL serum AND full 2.7 mL tube or 1 mL plasma aliquot
Turnaround time2 - 4 days
Storage / transportFrozen preferred, refrigerated acceptable

Also known as: Heparin Antibodies; Heparin Associated Thrombocytopenia and Thrombosis; Heparin Associated Thrombosis (HAT); Heparin Dependent Antiplatelet Antibodies; Heparin Induced Serotonin Release Assay; Heparin Induced Thrombosis (HIT); Heparin Serotonin Release Assay; Platelet Aggregation Factor; Platelet Aggregation Factor, Heparin Dependent; SRA (Serotonin Release Assay); Serotonin Release, Heparin-Induced; Serotonin Secretion Assay for HAT; Heparin-Dependent Platelet Antibody (SRA) - Unfractionated Heparin

Use

Detection of heparin-dependent platelet antibodies.

Collection instructions

Screen for Heparin Antibody Assay (HITAB) will be performed. If the Heparin Antibody Assay is negative the Serotonin Release Assay will be cancelled with a comment added to both test orders indicating the reason for cancellation. Collect Serotonin Release Assay specimen in a red top tube; do not use SST tube. Centrifuge, aliquot serum into a plastic vial and freeze. Citrated or ACD plasma specimen is acceptable if serum is not available. Specify Lovenox® (LMWH) or Unfractionated Heparin (UFH).

Reference range

Negative. A positive result requires >20% release of serotonin with low dose heparin and

Section

Sendout Testing

Performed

Monday - Friday

Contraindications

This test is not indicated if the Heparin Antibody Assay (HITAB) is negative.

NY State approved

No

Performing Laboratory

Sendout Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 82542

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation