Michigan Medicine Laboratories (MLabs) test REDST, CPT 84376. Specimen: 10 mL liquid stool..

Reducing Substances, Stool is Michigan Medicine Laboratories (MLabs) test code REDST, billed with CPT 84376. Specimen: 10 mL liquid stool.. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeREDST
CPT84376
LOINC—
Specimen10 mL liquid stool.
Volume10 mL liquid stool.

Use

Testing for reducing substances in stool is used in diagnosing the cause of diarrhea in children. Increased reducing substances in stool are consistent with primary or secondary disaccharidase deficiency and intestinal monosaccharide malabsorption. Similar intestinal absorption deficiencies are associated with short bowel syndrome and necrotizing enterocolitis. Stool reducing substances is also helpful in diagnosing between osmotic diarrhea caused by abnormal excretion of various sugars as opposed to diarrhea caused by viruses and parasites.

Collection instructions

Collect liquid stool in a plastic urine container or screw top stool container. Refrigerate. Do not collect and dispense from disposable diaper; stool liquid (which would be absorbed in diaper) is most important part of sample. Formed stool not acceptable.

Reference range

Negative. A result of 0.25% to 0.5% is suspicious for a carbohydrate absorption abnormality, >= 0.75% is abnormal.

Limitations

Assay results have relevance for liquid stool samples; assay results have little relevance for formed stool samples. Salicylates, penicillin, streptomycin, cephalosporins, ascorbic acid may interfere with assay and/or cause false positive results.

Section

Special Chemistry

Performed

Daily

NY State approved

No

Performing Laboratory

Immunology & Special Chemistry

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 84376

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation