Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Point of Care- Basic Panel, i-Stat

Point of Care- Basic Panel, i-Stat: Michigan Medicine Laboratories (MLabs) test PIBMP

Michigan Medicine Laboratories (MLabs) test PIBMP, CPT 80051. Specimen: 3 mL whole blood. Turnaround: 2 minutes.

Point of Care- Basic Panel, i-Stat is Michigan Medicine Laboratories (MLabs) test code PIBMP, billed with CPT 80051. Specimen: 3 mL whole blood. Turnaround time: 2 minutes. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Quest Diagnostics, ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codePIBMP
CPT80051
LOINC—
Specimen3 mL whole blood
Volume3 mL whole blood
Turnaround time2 minutes

Use

Performed at authorized locations by point of care operators. Panel includes: Sodium, Potassium, Chloride, Glucose, Urea Nitrogen, and Hematocrit. Sodium- monitoring electrolyte imbalances. Potassium- monitoring and aiding in the diagnosis of diseases and clinical conditions that manifest high and low potassium levels. Chloride- used in the diagnosis, monitoring, and treatment of electrolyte and metabolic disorders (e.g., cystic fibrosis, diabetic acidosis, and hydration disorders. Ionized Calcium- aids in the diagnosis and treatment of parathyroid disease, bone disease, chronic renal disease and tetany. Glucose- used in the diagnosis, monitoring and treatment of carbohydrate metabolism…

Collection instructions

Collect in lithium heparin syringe/tube.

Reference range

Analyte reference ranges are available in the i-Stat test procedure located on the POC website: https://www.pathology.med.umich.edu/point-of-care .

Limitations

•Specimens must be free of clots and fibrin strands. •Prolonged tourniquet application (venous stasis) and forearm exercise may decrease pH due to localized production of lactic acid. This in turn can affect ionized calcium. •Results may be affected in the following situations: hemolysis, traumatic draw, pumping fist during draw, extended delay between drawing and testing specimen, exposure to air, and obtaining specimen from an arm with an IV. •Results outside the reportable ranges for the system will be display with a "<" or ">" symbol.

Section

Point-of-Care Testing

NY State approved

No

Performing Laboratory

Point-of-Care Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 80051

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.