Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Point of Care- Occult Blood Stool

Point of Care- Occult Blood Stool: Michigan Medicine Laboratories (MLabs) test PHCLT

Michigan Medicine Laboratories (MLabs) test PHCLT. Turnaround: 1 minute.

Point of Care- Occult Blood Stool is Michigan Medicine Laboratories (MLabs) test code PHCLT. Turnaround time: 1 minute. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codePHCLT
CPT2335-8
LOINC—
Turnaround time1 minute

Use

Performed at authorized locations by point of care operators. Used to monitor gastrointestinal bleeding in patients with iron deficiency anemia or recuperating from surgery, peptic ulcer, ulcerative colitis and other conditions. It is not a test for colorectal cancer or other specific diseases.

Collection instructions

1. Identification- follow positive patient identification procedure. Apply patient demographic label or write at least two unique patient identifiers on the front of the slide in space provided. 2.Using applicator provided, collect small fecal sample. 3. Apply thin smear covering Box A. 4. Reuse applicator to obtain second sample from a different part of the specimen. 5. Close cover flap. Dispose of applicator in waste container.

Reference range

Negative

Limitations

•Bowel lesions, including some polyps and colorectal cancers, may not bleed at all or may bleed intermittently. Also, blood, if present may not be distributed uniformly in the fecal specimen. Consequently, a test result may be negative when disease is present. •Substances that can cause false-positives results: Red meat, Aspirin (> 325 mg/day), non-steroidal anti-inflammatory drugs (e.g., ibuprofen, indomethacin, and naproxen), Corticosteroids, phenylbutazone, reserpine, anticoagulants, antimetabolites, and caner chemotherapy drugs, excess alcohol consumption, and application of antiseptic preparations containing iodine. •Substances that can cause false-negative results: Ascorbic acid (>250…

Section

Point-of-Care Testing

NY State approved

No

Performing Laboratory

Point-of-Care Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation