Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Point of Care- Ferning, PPM

Point of Care- Ferning, PPM: Michigan Medicine Laboratories (MLabs) test PFERN

Michigan Medicine Laboratories (MLabs) test PFERN, CPT 54452, 72269.

Point of Care- Ferning, PPM is Michigan Medicine Laboratories (MLabs) test code PFERN, billed with CPT 54452, 72269. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codePFERN
CPTpH (72269-4), Ferning (54452-8)
LOINC—

Use

Performed by authorized providers in the point of care. Used to assess for premature amniotic fluid leakage: i.e. PROM (Premature Rupture of Membranes) or PPROM (Preterm Premature Rupture of Membranes).

Reference range

Negative

Limitations

•Cellar debris and blood in the sample may inhibit crystallization of amniotic fluid, and cause a false negative. •"Ferning" is not specific for amniotic fluid. Other fluids (e.g., blood cervical mucus, semen and some urine specimens) when dried can also yield microscopic crystallizations in a "fern" pattern, and cause false positives. •Prolonged rupture of membranes (greater than 24 hours) or slow, minimal leaks can yield false negative results.

Section

Point-of-Care Testing

NY State approved

No

Performing Laboratory

Point-of-Care Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation