Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Estimated Glomerular Filtration Rate, Creatinine-based

Estimated Glomerular Filtration Rate, Creatinine-based: Michigan Medicine Laboratories (MLabs) test Non-orderable - GFR

Michigan Medicine Laboratories (MLabs) test Non-orderable - GFR. Specimen: 1 mL. Turnaround: 2 hours.

Estimated Glomerular Filtration Rate, Creatinine-based is Michigan Medicine Laboratories (MLabs) test code Non-orderable - GFR. Specimen: 1 mL. Turnaround time: 2 hours. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeNon-orderable - GFR
CPT—
LOINC—
Specimen1 mL
Volume1 mL
Turnaround time2 hours

Use

Effective 01/05/2022, Michigan Medicine adopted an updated CKD-EPI equation for estimated glomerular filtration rate (eGFR) that does not include race as a variable. All eGFR results will be expressed as a single “eGFR” and no longer distinguish between “eGFR, Black” and “eGFR, Non-Black”. There is consensus that elimination of the race modifier used to calculate “eGFR, Black” is appropriate given that race is a social and not a biologic construct. The National Kidney Foundation (NKF) and American Society of Nephrology (ASN) Task Force on Reassessing the Inclusion of Race in Diagnosing Kidney Disease affirmed this position in a formal release on 9/23/2021 (Delgado C, et al. A Unifying…

Collection instructions

Collect specimen in an SST tube. Centrifuge within 4 hours of collection, aliquot serum into a plastic vial and refrigerate. If specimen cannot be centrifuged at client site, please arrange for delivery to MLabs within 3 hours of specimen collection.

Reference range

2021 CKD-EPI ≥ 60 mL/min/1.73m^2 GFR Category: GFR (mL/min/1.73m^2): Interpretation: G1 90 or greater Normal or high* G2 60-89 Mild decrease* G3a 45-59 Mild to moderate decrease G3b 30-44 Moderate to severe decrease G4 15-29 Severe decrease G5 14 or less Kidney failure *In the absence of evidence of kidney damage, neither GFR category G1 nor G2 fulfill the criteria for CKD (Kidney Int Suppl 2013;3:1-150)

Limitations

2021 CKD-EPI calculations are not valid for patients less than 18 years of age and for pregnant women. The 2021 CKD-EPI formula used to calculate the EGFR result has not been validated in patients > 100 years of age. EGFR is not calculated when serum creatinine values are <0.1mg/dL [11/20] The EGFR should NOT be used for pharmacy drug dosing. The calculation is not useful for estimating GFR in unstable patients or patients with acute renal failure. There are other conditions where the EGFR will be less accurate and should not be utilized. These include: extremes of body size and weight, skeletal muscle disease, paraplegia or quadriplegia, vegetarian diet, and for the calculation of dose…

Section

Clinical Chemistry

Performed

Daily, 24 hours

Contraindications

GFR estimate can be interpreted accurately only during a steady state of creatinine balance. GFR estimate will overestimate true GFR if serum creatinine is rising (such as acute kidney failure) and will underestimate true GFR if serum creatinine is declining (such as resolution of acute kidney failure).

NY State approved

No

Performing Laboratory

Clinical Core Laboratory

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation