Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › NLGN4X Gene Sequencing

NLGN4X Gene Sequencing: Michigan Medicine Laboratories (MLabs) test NLGN4

Michigan Medicine Laboratories (MLabs) test NLGN4, CPT 81405. Specimen: 5 mL whole blood. Turnaround: 21 - 28 days.

NLGN4X Gene Sequencing is Michigan Medicine Laboratories (MLabs) test code NLGN4, billed with CPT 81405. Specimen: 5 mL whole blood. Turnaround time: 21 - 28 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, Quest Diagnostics, ARUP Laboratories.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeNLGN4
CPT81405
LOINC—
Specimen5 mL whole blood
Volume5 mL whole blood
Turnaround time21 - 28 days
Storage / transportRoom temperature up to 24 hours or 2-8°C up to 5 days for blood 2-36°C for saliva

Also known as: Asperger Syndrome Susceptibility; Autism Susceptibility; Neuroligin 4; Autism / Intellectual Disability

Use

Analysis for the presence of NLGN4X (OMIM:300427) mutations in patients with a phenotype consistent with Autism susceptibility, X-linked 2 (OMIM:300495) or Asperger Syndrome susceptibility, X-linked 2 (OMIM:300497). See NCBI Gene for additional details.

Collection instructions

Collect blood specimen in a EDTA lavender top tube. Send it within 24 hours if stored at room temperature or within 5 days if stored refrigerated. Fill out a MLabs Molecular test requisition (or place an e-order if applicable): https://mlabs.umich.edu/media/166 Fill out a Clinical History Form for Insurance Prior Authorization (include all required documentation indicated at the bottom of this form): https://mlabs.umich.edu/sites/default/files/2020-08/file/mlab11618clini… Fill out a UMHS Request and Consent for Genetic Testing form: https://mlabs.umich.edu/sites/default/files/2023-04/file/germline-conse… Michigan State law requires the ordering provider to obtaining informed consent from the patient prior to prognostic or predictive genetic testing. Contact a MLabs Client Services Center at 800-862-7284 to request paper copies or to setup a client account.

Reference range

Interpretive report provided.

Limitations

This assay will not detect large deletions in the NLGN4X gene or intronic mutations outside the region sequenced in the NLGN4X gene. Variant classification reflects the current state of scientific understanding at the time of test completion. As new scientific data becomes available, the interpretation and classification of variants identified in this assay may change. Test interpretation may be impacted by the presence of a hematologic malignancy or an allogenic bone marrow transplant.

Section

MMGL Molecular Genetics

Performed

Monday - Friday

NY State approved

No

Alternate specimens

Saliva kit (Oragene OGD-510), follow collection instructions.

Performing Laboratory

MMGL

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81405

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation