Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Germline MLH1 Promoter Methylation

Germline MLH1 Promoter Methylation: Michigan Medicine Laboratories (MLabs) test MLH1G

Michigan Medicine Laboratories (MLabs) test MLH1G, CPT 81288. Specimen: 6 mL EDTA whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.. Turnaround: 3 - 10 days.

Germline MLH1 Promoter Methylation is Michigan Medicine Laboratories (MLabs) test code MLH1G, billed with CPT 81288. Specimen: 6 mL EDTA whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.. Turnaround time: 3 - 10 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: ARUP Laboratories, Cleveland Clinic Laboratories, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeMLH1G
CPT81288
LOINC—
Specimen6 mL EDTA whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Volume6 mL EDTA whole blood. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time3 - 10 days

Also known as: Hereditary Nonpolyposis Colorectal Cancer (HNPCC); Lynch Syndrome

Use

Hereditary nonpolyposis colorectal cancer (HNPCC), also known as Lynch Syndrome, is an autosomal dominant condition associated with increased risk of multiple cancers particularly colorectal and endometrial. This syndrome most commonly results from mutations of genes encoding DNA mismatch repair proteins including MLH1, MSH2, MSH6 and PMS2. These mutations lead to tumors with microsatellite instability (MSI) – a change in length of a microsatellite allele due to either insertion or deletion of repeating units. MSI can also occur in sporadic colorectal, endometrial and other cancers in patients without HNPCC. In sporadic cancers, MSI is typically associated with silenced MLH1 protein…

Collection instructions

Collect blood in a lavender top tube. Refrigerate and send intact blood or bone marrow specimen within 24 hours of collection.

Reference range

Interpretive report provided.

Limitations

Specimens submitted for Molecular Diagnostics testing may contain substances that can inhibit PCR gene amplification. If an inhibitor is known to be present, attempts will be made to clear the specimen of inhibitor prior to amplification. Known inhibitors include heparin, medications and some levels of hemoglobin or IgG. The major inhibitor we see in our laboratory is heparin; avoid drawing blood in a heparin tube or through a heparinized port. For molecular diagnostics testing, a lavender top (EDTA) tube is preferred. If specimens containing heparin must be submitted, note "heparin" on the requisition to alert the lab to 'clean' the specimen before analysis thus reducing turnaround time,…

Section

Molecular Diagnostics

Performed

Monday - Friday

NY State approved

No

Alternate specimens

The preferred specimen is EDTA (purple top); ACD (yellow top) is also acceptable. The assay will be attempted on Green top (sodium or lithium heparin) tubes, but the test may fail due to inhibition of PCR by heparin and an inadequate result will be issued in a report. Extracted DNA, from peripheral blood is acceptable.

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81288

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation