Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › Hepatocellular Carcinoma Risk Panel with GALAD Score

Hepatocellular Carcinoma Risk Panel with GALAD Score: Michigan Medicine Laboratories (MLabs) test MHCCG

Michigan Medicine Laboratories (MLabs) test MHCCG, CPT 82107, 83951. Specimen: 0.5 mL serum. Turnaround: 2 - 5 days.

Hepatocellular Carcinoma Risk Panel with GALAD Score is Michigan Medicine Laboratories (MLabs) test code MHCCG, billed with CPT 82107, 83951. Specimen: 0.5 mL serum. Turnaround time: 2 - 5 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Cleveland Clinic Laboratories, ARUP Laboratories, Quest Diagnostics, Labcorp.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeMHCCG
CPT82107, 83951
LOINC—
Specimen0.5 mL serum
Volume0.5 mL serum
Turnaround time2 - 5 days
Storage / transportFrozen preferred, refrigerated acceptable

Use

This test includes a GALAD (gender, age, alpha-fetoprotein [AFP]-L3, AFP, des-gamma-carboxy prothrombin [DCP]) model score calculation to calculate the probability of hepatocellular carcinoma (HCC). The GALAD model has been demonstrated to have higher diagnostic accuracy for the detection of HCC when compared to the use AFP, AFP-L3, and DCP markers alone or in combination. The performance of the GALAD score has also been reported to be superior to ultrasound for HCC detection.

Collection instructions

Collect specimen in an SST or red top tube. Spin and aliquot into a screw capped plastic tube. Send to Specimen Processing frozen

Reference range

TOTAL ALPHA-FETOPROTEIN (AFP):<4.7 ng/mL AFP L3-PERCENT:<10% DES-GAMMA-CARBOXY PROTHROMBIN:<7.5 ng/mL GAL1:Not applicable GAL2:Not applicable

Section

Sendout Testing

Performed

Monday, Wednesday, Friday

Contraindications

GALAD score testing (this test) should not be performed for pregnant patients as alpha-fetoprotein results are elevated during pregnancy.

NY State approved

No

Performing Laboratory

Sendout Testing

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 82107, 83951

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation