Michigan Medicine Laboratories (MLabs) test MECD, CPT 81304. Specimen: 5 mL whole blood. Turnaround: 21 - 28 days.

MECP2 Deletion / Duplication Analysis is Michigan Medicine Laboratories (MLabs) test code MECD, billed with CPT 81304. Specimen: 5 mL whole blood. Turnaround time: 21 - 28 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI). Other labs in the directory with tests billed under the same CPT: Labcorp, OHSU Laboratory Services.
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeMECD
CPT81304
LOINC—
Specimen5 mL whole blood
Volume5 mL whole blood
Turnaround time21 - 28 days
Storage / transportRoom temperature up to 24 hours or 2-8°C up to 5 days for blood 2-36°C for saliva

Also known as: MECP2 Del/Dup Analysis; Rett Syndrome; MECP2 Deletion; MECP2 Duplication; MECP2 Gene Deletion and Duplication Analysis; Autism / Intellectual Disability

Use

This test is used to detect the presence of MECP2 (OMIM:300005) deletions and duplications. MECP2 gene deletion and duplication analysis can be performed on patients with negative MECP2 sequence analysis or relatives of a patient with a known MECP2 deletion/duplication variant. Approximately 30% of patients with Rett syndrome (OMIM:312750) and 7% of patients with atypical Rett syndrome have a deletion copy number variant (CNV) within or encompassing the MECP2 gene (Laccone et al., Hum Mutat. 2004; 23:234–44; Archer et al., J Med Genet. 2006; 43:451–6). In addition, MECP2 duplication CNVs have been reported in approximately 2.5% of males with severe intellectual disability (PMID: 16080119;…

Collection instructions

Collect blood specimen in a EDTA lavender top tube. Send it within 24 hours if stored at room temperature or within 5 days if stored refrigerated. Fill out a MLabs Molecular test requisition (or place an e-order if applicable): https://mlabs.umich.edu/media/166 Fill out a Clinical History Form for Insurance Prior Authorization (include all required documentation indicated at the bottom of this form): https://mlabs.umich.edu/sites/default/files/2020-08/file/mlab11618clini… Fill out a UMHS Request and Consent for Genetic Testing form: https://mlabs.umich.edu/sites/default/files/2023-04/file/germline-conse… Michigan State law requires the ordering provider to obtaining informed consent from the patient prior to prognostic or predictive genetic testing. Contact a MLabs Client Services Center at 800-862-7284 to request paper copies or to setup a client account.

Reference range

Interpretive report provided.

Limitations

This assay will not detect point mutations or frame-shift mutations in the MECP2 gene. This analysis may not identify variants in the regulatory elements or deep intronic regions of the targeted gene(s) or other regions of the genome that are not included in this test. This assay may not detect small copy number variants (1-2 exons), or balanced inversion/translocations involving the targeted gene(s). Variant classification reflects the current state of scientific understanding at the time of test completion. As new scientific data becomes available, the interpretation and classification of variants identified in this assay may change. Test interpretation may be impacted by the presence of…

Section

MMGL Molecular Genetics

Performed

Monday - Friday

NY State approved

No

Alternate specimens

Cheek swab kit (Oragene OCD-100), follow collection instructions. Saliva kit (Oragene OGD-510), follow collection instructions.

Performing Laboratory

MMGL

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Other tests billed with CPT 81304

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation