Clinical laboratory consulting in all 50 states, remote and on-site Call (602) 874-1311
Menu
Sound Lab Consultantsby Sound Lab Consultants
Sound Lab Consultants › National Lab Test Directory › Michigan Medicine Laboratories (MLabs) › BMT Engraftment Analysis, Pre-BMT, Donor

BMT Engraftment Analysis, Pre-BMT, Donor: Michigan Medicine Laboratories (MLabs) test DONBM

Michigan Medicine Laboratories (MLabs) test DONBM. Specimen: 6 mL EDTA whole blood; 3 mL EDTA bone marrow. Extracted DNA is also acceptable if extracted in a CLIA certified laborato. Turnaround: 2 - 7 days.

BMT Engraftment Analysis, Pre-BMT, Donor is Michigan Medicine Laboratories (MLabs) test code DONBM. Specimen: 6 mL EDTA whole blood; 3 mL EDTA bone marrow. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.. Turnaround time: 2 - 7 days. Performing laboratory: Michigan Medicine Laboratories (MLabs), CLIA 23D0366712 (Ann Arbor, MI).
LaboratoryMichigan Medicine Laboratories (MLabs)
CLIA number23D0366712
Test codeDONBM
CPT—
LOINC—
Specimen6 mL EDTA whole blood; 3 mL EDTA bone marrow. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Volume6 mL EDTA whole blood; 3 mL EDTA bone marrow. Extracted DNA is also acceptable if extracted in a CLIA certified laboratory.
Turnaround time2 - 7 days

Also known as: Bone Marrow Transplant Engraftment Evaluation; Polymorphism Detection, pre-BMT; Pre-BMT Engraftment Analysis, Donor; Pre-BMT Polymorphism Detection; VNTR for pre-BMT Engraftment Analysis; Donor BM Engraph. Eval; Chimerism Analysis, Pre-Transplant, Donor

Use

To detect genetic polymorphism between the patient (recipient) and the donor prior to the bone marrow transplant, in order to evaluate the engraftment status after the transplant.

Collection instructions

Collect blood or bone marrow in lavender top tube. Send intact specimen at room temperature or refrigerated.

Reference range

Interpretive report provided. A combined report for the recipient and donor is issued under the patient (recipient) medical record number; no separate report is issued for the donor.

Limitations

If the patient has a very low white blood cell count, the DNA yield may be insufficient to complete the analysis. In order to perform this test, both the patient's pre-transplant and the donor's specimen must be available. Specimens submitted for Molecular Diagnostics testing may contain substances that can inhibit PCR gene amplification. If an inhibitor is known to be present, attempts will be made to clear the specimen of inhibitor prior to amplification. Known inhibitors include heparin, medications and some levels of hemoglobin or IgG. The major inhibitor we see in our laboratory is heparin; avoid drawing blood in a heparin tube or through a heparinized port. For molecular diagnostics…

Section

Molecular Diagnostics

NY State approved

No

Alternate specimens

The preferred specimen is EDTA (purple top); ACD (yellow top) is also acceptable. The assay will be attempted on Green top (sodium or lithium heparin) tubes, but the test may fail due to inhibition of PCR by heparin and an inadequate result will be issued in a report. Extracted DNA is acceptable. [rev 3/10; 8/15]

Performing Laboratory

Molecular Diagnostics

View this test on Michigan Medicine Laboratories (MLabs)'s website → · Last checked 2026-11-29

Search the National Lab Test Directory · All Michigan Medicine Laboratories (MLabs) tests and CLIA locations

Run a CLIA-certified lab? Add your test menu free. Upload your tests with our CSV template and reach clinics, physicians and labs searching by test name and CPT code. Submit your lab's test menu →
Test information is summarized from each laboratory's publicly published test menu, or uploaded by the laboratory, and linked to the original source. Requirements change: always confirm specimen and ordering details with the performing laboratory before collection. Sound Lab Consultants is not affiliated with the laboratories listed. CPT is a registered trademark of the American Medical Association. LOINC is a registered trademark of Regenstrief Institute, Inc.
Setting up or running a lab? Get it right the first time.

Sound Lab Consultants handles CLIA applications, state licensing, director coverage, validations and survey prep, remotely or on site. Prefer software? MyLabCompliance.io tracks QC, competency and personnel files.

Book a free consultation